For connected CO
sensors the air flow will be steplessly controlled between mode 1 and 3 depending on the
2
measured PPM values: for a connected humidity sensor the air flow will be switched to mode 3 when this is
switched on.

7.3 Other settings for installer

In addition to the air flow, it is also possible to change other settings of the appliance; for an overview of these
settings of a standard appliance (®
Setting values appliance with Plus pcb
Changes can be carried out in the settings menu
Warning:
As changes in the settings menu can disrupt the proper functioning of the appliance,
changes of settings not described here require consultation with Ubbink NV
Incorrect settings may seriously affect the proper performance of the appliance!

7.4 Factory settings

It is possible to simultaneously revert all the changed settings back to the factory settings.
All changed settings are then back to the values they had when they left the factory; all message and fault codes
are also deleted from the service menu.
The filter message, however, is not reset!
For returning to factory settings, open the settings menu
Under appliance settings, the appliance can be returned to factory settings through step number 15.9.
Caution!:
With a Ubiflux Vigor W400 Plus, after resetting to the factory setting, step number 14.1 must be
reset to external Bus in the settings menu!
Setting values standard appliance
page 54).
.
Ubiflux Vigor W400 615912-D
page 51 ) and appliance with Plus pcb ( ®
.
Ubbink / 25