Setting Values; Setting Values Standard Appliance - ubbink Ubiflux Vigor W400 Installation Regulations

Hide thumbs Also See for Ubiflux Vigor W400:
Table of Contents

Advertisement

13 Setting values

13.1 Setting values standard appliance

The below setting values are for a Ubiflux Vigor W400-appliance without Plus pcb.
Step
Description
No
1
Flow rate
1.1
Air flow rate setting 0
1.2
Air flow rate setting 1
1.3
Air flow rate setting 2
1.4
Air flow rate setting 3
1.5
Imbalance permissible
1.6
Imbalance (Open fireplace)
1.7
Offset supply
1.8
Offset exhaust
1:19
Default fan setting
2
Bypass
2.1
Mode Bypass
2.2
Bypass temperature "from
dwelling"
2.3
Bypass temperature "from
outside"
2.4
Bypass hysteresis
2.5
Mode Bypass boost
2.6
Fan setting selection Bypass
boost
3
Frost protection
3.1
Frost temperature
3.2
Minimum intake temperature
4
Filter message
Factory settings
Setting range
50 m³/h
0 or adjustable between 50 m³/h and 400
m³/h (never higher than step no. 1.2)
100 m³/h
Adjustable between 50 m³/h and 400
m³/h (not higher than step no. 1.3 or
lower than step no. 1.1)
200 m³/h
Adjustable between 50 m³/h and 400
m³/h (not higher than step no. 1.4 or
lower than step no. 1.2)
300 m³/h
Adjustable between 50 m³/h and 400
m³/h (not lower than step no. 1.3)
Yes
Yes / No
0%
0% / +20%
0%
-15% / +15% fan setting
0%
-15% / +15% fan setting
1
0 or 1
Automatic
- Automatic
- Bypass closed
- Bypass open
24 °C
15 °C / 35 °C
10°C
7 °C / 15 °C
2 °C
0 °C / 5 °C
Off
On / Off
3
0 / 3
0 °C
-1,5 °C /1,5 °C
10 °C
7 °C /22 °C
Ubiflux Vigor W400 615912-D
Comment
Value calculated
back to set flow
rate, see screen
Ubbink / 51