Installing The Unit - Samsung AR36BSHUMGMX Installation Manual

Table of Contents

Advertisement

Safety Information
Safety Information

Installing the unit

WARNING
IMPORTANT: When installing the unit, always remember to
connect first the refrigerant tubes, then the electrical lines.
• Connecting one indoor unit to this product is prohibited.
• Upon receipt, inspect the product to verify that it has not
been damaged during transport. If the product appears
damaged, DO NOT INSTALL it and immediately report
the damage to the carrier or retailer (if the installer or the
authorized technician has collected the material from the
retailer.)
• After completing the installation, always carry out a
functional test and provide the instructions on how to
operate the air conditioner to the user.
• Do not use the air conditioner in environments with
hazardous substances or close to equipment that release
free flames to avoid the occurrence of fires, explosions or
injuries.
• Our units should be installed in compliance with the spaces
shown in the installation manual, to ensure accessibility
from both sides and allow repairs or maintenance
operations to be carried out. The unit's components should
be accessible and easy to disassemble without endangering
people and objects.
• For this reason, when provisions of the installation manual
are not complied with, the cost required to access and repair
the units (in SAFETY CONDITIONS, as set out in prevailing
regulations) with harnesses, ladders, scaffolding or any
other elevation system will NOT be considered part of the
warranty and will be charged to the end customer.
• Make sure that the condensed water runs well out of the
unit at low ambient temperature. Drain pipe and cond heater
can frost/ice can not grow. If drain work is not effective
for releasing condensed water, it can make the units get
damaged by massive ice and system can be stop, covered by
ice. (AC018/024BXADCH models)
• Do not disassemble and alter the heater at your own
discretion. (For AC018/024BXADCH models)
4
English
DB68-11579A-00_IM_RAC oudoor_AA_EN_.indd 4
DB68-11579A-00_IM_RAC oudoor_AA_EN_.indd 4
Power supply line, fuse or circuit breaker
WARNING
• Always make sure that the power supply is compliant
with current safety standards. Always install the air
conditioner in compliance with current local safety
standards.
• Always verify that a suitable earthing connection is
available.
• Verify that the voltage and frequency of the power
supply comply with the specifications and that the
installed power is sufficient to ensure the operation of
any other domestic appliance connected to the same
electric lines.
• Always verify that the cut-off and protection switches
are suitably dimensioned.
• Verify that the air conditioner is connected to the
power supply in accordance with the instructions
provided in the wiring diagram included in the manual.
• Always verify that electric connections (cable entry,
section of leads, protections...) are compliant with
the electric specifications and with the instructions
provided in the wiring scheme. Always verify that all
connections comply with the standards applicable to
the installation of air conditioners.
• Devices disconnected from the power supply should
be completely disconnected in the condition of
overvoltage category.
• Be sure not to perform power cable modification,
extension wiring, and multiple wire connection.
– It may cause electric shock or fire due to poor
connection, poor insulation, or current limit
override.
– When extension wiring is required due to power
line damage, refer to "Step 5 Optional: Extending
the power cable" in the installation manual.
2022-01-12 오후 1:37:48