Floor Protection - Drolet DB03411 Owner's Manual

Hide thumbs Also See for DB03411:
Table of Contents

Advertisement

4. Floor Protection

This stove is meeting the requirements of CAN/ULC-S627 and is suitable for installation on a
combustible floor. However, it must be placed on a non-flammable surface to protect the floor
from hot embers that may fall during loading.
The floor protection must be a continuous, non combustible material, such as steel with a minimum
thickness of 0.015" (0.38 mm) or ceramic tiles sealed together with grout. Cement board, brick, or
any other approved or listed material suited for floor protection. No R factor required.
Any type of tile will require a continuous non combustible sheet beneath to prevent the possibility
of embers falling through to the combustible floor if cracks or separation should occur in the
finished surface. Check local codes for approved alternatives. No protection is required if the
unit is installed on a non-combustible floor (ex: concrete).
Canada
G
8" (203 mm)
2
H
8" (203 mm)
I
18" (457 mm) From
door opening
J
N/A
K
40 ¼" (1020 mm)
N
N/A
3
S
52 7/8" (1343 mm)
T
37 3/8" (949 mm)
U
40 ¼" (1020 mm)
V
73" (1854 mm)
V
In Canada, to comply with CSA B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment, any combustible covering beneath the
1
appliance and/or within the area extending horizontally at least 450 mm (18 in) beyond the appliance on any side equipped with a door, and at least
200 mm (8 in) beyond the appliance on other sides, shall be protected by a continuous, durable, non-combustible pad that will ember protection. The
450 mm (18 in) ember protection required on any side with a door shall extend for the full width of the appliance plus the 200 mm (8 in) required
on each side of the appliance without a door. Where the appliance is installed less than 200 mm (8 in) from a wall, the ember pad need only extend
to the base of the wall. An ember pad shall not be placed on top of a carpet unless the pad is structurally supported to prevent displacement and
distortion.
2
The floor protection at the back of the stove is limited to the stove's required clearance if such clearance is smaller than 8 inches (203 mm).
3
Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm).
Page 20
FLOOR PROTECTION
USA
1
N/A
N/A
16" (406 mm) From
door opening
8" (203 mm)
30 ½" (775 mm)
See note 3
42 7/8" (1089 mm)
30 3/8" (772 mm)
30 ½" (775 mm)
58 1/8" (1476 mm)
T
U
I
K
Figure 19: Floor Protection
Ve
Ho
84"
213 cm
N
Installation and Operation Requirements - Black Stag II
G
H
S
J

Advertisement

Table of Contents
loading

This manual is also suitable for:

Black stag ii

Table of Contents