OPERATION REQUIREMENTS
(DB03182 model)
US Environmental Protection Agency
phase II certified wood stove compliant
with 2020 cord wood standard
Safety tested according to ULC S627,
UL 1482 and UL 737 standards by an
accredited laboratory.
MOBILE
HOME
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS
IN LOCAL AREA.
READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD STOVE. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
READ AND KEEP THIS MANUAL FOR REFERENCE
46242I_A
Printed in Canada
2021-06-29

Advertisement

Table of Contents
loading

Summary of Contents for Drolet ESCAPE 1200

  • Page 1 Wood Stove Owner's Manual Part 2 of 2 INSTALLATION AND ESCAPE 1200 OPERATION REQUIREMENTS (DB03182 model) US Environmental Protection Agency phase II certified wood stove compliant with 2020 cord wood standard Safety tested according to ULC S627, UL 1482 and UL 737 standards by an accredited laboratory.
  • Page 2 If it can not be provided, the warranty period will be determined by the date of manufacture of the product. It is also highly recommended to register the warranty online at https://www.drolet.ca/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit.
  • Page 3: Table Of Contents

    7.1 Replacement ........................29 7.2 Gasket ..........................30 7.3 Door ..........................30 7.3.1 Adjustment ......................30 7.3.2 Door Alignment ......................31 7.3.3 Gasket ........................32 8. Exploded Diagram and Parts List ..................33 DROLET LIMITED LIFETIME WARRANTY...................36 Installation and Operation Manual - Escape 1200 Page 3...
  • Page 4: Certification Plate

    1. CERTIFICATION PLATE Page 4 Installation and Operation Manual - Escape 1200...
  • Page 5 Installation and Operation Manual - Escape 1200 Page 5...
  • Page 6: General Information

    Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA on February 28 , 2018. Carbon monoxide. Page 6 Installation and Operation Manual - Escape 1200...
  • Page 7: Specifications

    Z240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA on February 28 , 2018. Installation and Operation Manual - Escape 1200 Page 7...
  • Page 8: Dimensions

    153mm Figure 1: Top View 28 7/8" 732mm 22 3/4" 578mm 8 1/2" 216mm 10 1/4" 260mm 20 5/8" 523mm 15 3/4" 400mm Figure 2: Front View Figure 3: Side View Page 8 Installation and Operation Manual - Escape 1200...
  • Page 9: Combustion Chamber Dimensions

    12" 305mm Figure 4: Door Opening 1/4" 3/16" 11 3/4" 298mm 14 1/4" 19 1/8" 360mm 484mm Figure 5: Front View - Combustion Chamber Figure 6: Side View - Combustion Chamber Installation and Operation Manual - Escape 1200 Page 9...
  • Page 10: Epa Loading

    Leave to burn with the primary air control open for approximately 10 minutes and then close the primary air control completely for the low burn rate and halfway for the medium burn rate. Page 10 Installation and Operation Manual - Escape 1200...
  • Page 11: Clearances To Combustible Material

    13 ½" (343 mm) 13 ½" (343 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Manual - Escape 1200 Page 11...
  • Page 12 48" Flush 48" 36" 122 cm 92 cm Figure 7: Clearances - Top Figure 8: Clearances - Corner 84" 213 cm Figure 9: Clearances - Side Page 12 Installation and Operation Manual - Escape 1200...
  • Page 13: With Heat Shield Ac02762

    6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall pipe connector can be used. The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Manual - Escape 1200 Page 13...
  • Page 14: With Lowered Ceiling

    14 ½" (368 mm) 14 ½" (368 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 14 Installation and Operation Manual - Escape 1200...
  • Page 15: With Heat Shield Ac02762 And Lowered Ceiling

    The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Manual - Escape 1200 Page 15...
  • Page 16: Inside A Combustible Alcove

    16 ½" (419 mm) 16 ½" (419 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 16 Installation and Operation Manual - Escape 1200...
  • Page 17: Mobile Home With Heat Shield Ac02762

    Les distances de tuyau listées dans ce tableau se réfèrent aux distances obtenues lorsque le poêle est installé en accord avec les dégagements de l’appareil mentionnés ci-dessus. Installation and Operation Manual - Escape 1200 Page 17...
  • Page 18: Floor Protection

    The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm). Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm). Page 18 Installation and Operation Manual - Escape 1200...
  • Page 19: Reducing Wall And Ceiling Clearances Safely

    G) Edge clearance for ceiling shields to side and back walls: 3" (75 mm) Shield extension beyond each side appliance: 18" (450 mm). Figure 11: Heat shield clearances Figure 12: Heat shield clearances Installation and Operation Manual - Escape 1200 Page 19...
  • Page 20 Figure 13: Heat shield clearances Figure 14: Heat shield clearances Page 20 Installation and Operation Manual - Escape 1200...
  • Page 21 Brick, with a minimum of 24 gauge (0.61 mm) sheet metal backing, spaced out at least 1" (25 mm)* by non-combustible spacers 12" (305 mm) * In Canada this space can be ⅞" (21 mm) Installation and Operation Manual - Escape 1200 Page 21...
  • Page 22: Options Installation On Your Product

    6. OPTIONS INSTALLATION ON YOUR PRODUCT Page 22 Installation and Operation Manual - Escape 1200...
  • Page 23: Optional Fresh Air Intake Kit Installation

    (HVAC type, must meet ULC S110 or UL 181 class 0 or class 1) (B), sold separately. Refer to air intake kit installation instructions for more details. Installation and Operation Manual - Escape 1200 Page 23...
  • Page 24: Optional Fire Screen Installation

    Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the fire screen. Page 24 Installation and Operation Manual - Escape 1200...
  • Page 25: Optional Blower And Thermodisc Installation

    Ensure that the blower’s power cord is not in contact with any surface of the stove to prevent electrical shock or fire damage. Do not run the power cord beneath the stove. Installation and Operation Manual - Escape 1200 Page 25...
  • Page 26: Air Tubes And Baffle Installation

    Put the baffle in place. Repeat steps 1 and 2 for the three other tubes. To remove the tubes use the above steps in reverse order. Page 26 Installation and Operation Manual - Escape 1200...
  • Page 27 Note that secondary air tubes (B) can be replaced without removing the baffle board (A) and that all tube are not necessarely identical (look at the part number on the tube). Installation and Operation Manual - Escape 1200 Page 27...
  • Page 28: Mobile Home Installation

    Mobile Home Installation THE IMAGES SHOWN ARE INDICATIVE ONLY AND MAY DIFFER OF YOUR PRODUCT, BUT THE ASSEMBLY REMAINS THE SAME. Screw the base on the floor with the proper hardware (O). Page 28 Installation and Operation Manual - Escape 1200...
  • Page 29: Maintenance/Parts Replacement

    Reinstall the glass, being careful to centre the glass in the door and not to over-tightening the retaining screw. The two main causes of broken door glass are uneven placement in the door and over-tightening the retaining screws. Installation and Operation Manual - Escape 1200 Page 29...
  • Page 30: Gasket

    Remove the split pin by pulling and turning it using pliers. Turn the handle one counterclockwise turn to increase pressure. Reinstall the split pin with a small hammer. Figure 15: Removing the split pin Figure 16: Installing the split pin Page 30 Installation and Operation Manual - Escape 1200...
  • Page 31: Door Alignment

    Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. Configurations 1-2-3-4-5-6, show in which direction these act on the adjustment of the door. Installation and Operation Manual - Escape 1200 Page 31...
  • Page 32: Gasket

    Leave about ½" long of the gasket when cutting and press the end into the groove. Tuck any loose fibers under the gasket and into the silicone. Close the door. Do not use the stove for 24 hours. Page 32 Installation and Operation Manual - Escape 1200...
  • Page 33: Exploded Diagram And Parts List

    8. Exploded Diagram and Parts List Installation and Operation Manual - Escape 1200 Page 33...
  • Page 34 ESCAPE 1200 CAST IRON DOOR ASSEMBLY AC06500 SILICONE AND 5/8" X 8' BLACK DOOR GASKET KIT AC01420 RIGID FIRESCREEN PL06728 PAINTED AIR CONTROL HANDLE 30129 METAL SCREW #10 X 1/2" PAN QUADREX ZINC "A" TYPE Page 34 Installation and Operation Manual - Escape 1200...
  • Page 35 LEVELING BOLT 1/4 - 20 X 1'' 30185 17/64" AA TYPE WASHER BLACK 30100 BLACK HEX NUT 1/4 - 20 SE74266 ESCAPE 1200 PEDESTAL ASSEMBLY PL74268 BACK OF THE BASE SE74362 ESCAPE 1200 GLASS AND MOLDING KIT Installation and Operation Manual - Escape 1200 Page 35...
  • Page 36: Drolet Limited Lifetime Warranty

    Shall your unit or a component be defective, contact immediately your DROLET dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling: •...
  • Page 38 Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002 of information contained in any document obtained from https://www.drolet.ca/en/ unauthorized sources. tech@sbi-international.com...