Page 1
Wood Stove Owner's Manual Part 2 of 2 INSTALLATION AND ESCAPE 1200 OPERATION REQUIREMENTS (DB03182 model) US Environmental Protection Agency phase II certified wood stove compliant with 2020 cord wood standard Safety tested according to ULC S627, UL 1482 and UL 737 standards by an accredited laboratory.
Page 2
If it can not be provided, the warranty period will be determined by the date of manufacture of the product. It is also highly recommended to register the warranty online at https://www.drolet.ca/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit.
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA on February 28 , 2018. Carbon monoxide. Page 6 Installation and Operation Manual - Escape 1200...
Z240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA on February 28 , 2018. Installation and Operation Manual - Escape 1200 Page 7...
Leave to burn with the primary air control open for approximately 10 minutes and then close the primary air control completely for the low burn rate and halfway for the medium burn rate. Page 10 Installation and Operation Manual - Escape 1200...
13 ½" (343 mm) 13 ½" (343 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Manual - Escape 1200 Page 11...
Page 12
48" Flush 48" 36" 122 cm 92 cm Figure 7: Clearances - Top Figure 8: Clearances - Corner 84" 213 cm Figure 9: Clearances - Side Page 12 Installation and Operation Manual - Escape 1200...
6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall pipe connector can be used. The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Manual - Escape 1200 Page 13...
14 ½" (368 mm) 14 ½" (368 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 14 Installation and Operation Manual - Escape 1200...
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Installation and Operation Manual - Escape 1200 Page 15...
16 ½" (419 mm) 16 ½" (419 mm) The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 16 Installation and Operation Manual - Escape 1200...
Les distances de tuyau listées dans ce tableau se réfèrent aux distances obtenues lorsque le poêle est installé en accord avec les dégagements de l’appareil mentionnés ci-dessus. Installation and Operation Manual - Escape 1200 Page 17...
The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm). Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm). Page 18 Installation and Operation Manual - Escape 1200...
Page 21
Brick, with a minimum of 24 gauge (0.61 mm) sheet metal backing, spaced out at least 1" (25 mm)* by non-combustible spacers 12" (305 mm) * In Canada this space can be ⅞" (21 mm) Installation and Operation Manual - Escape 1200 Page 21...
(HVAC type, must meet ULC S110 or UL 181 class 0 or class 1) (B), sold separately. Refer to air intake kit installation instructions for more details. Installation and Operation Manual - Escape 1200 Page 23...
Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the fire screen. Page 24 Installation and Operation Manual - Escape 1200...
Ensure that the blower’s power cord is not in contact with any surface of the stove to prevent electrical shock or fire damage. Do not run the power cord beneath the stove. Installation and Operation Manual - Escape 1200 Page 25...
Put the baffle in place. Repeat steps 1 and 2 for the three other tubes. To remove the tubes use the above steps in reverse order. Page 26 Installation and Operation Manual - Escape 1200...
Page 27
Note that secondary air tubes (B) can be replaced without removing the baffle board (A) and that all tube are not necessarely identical (look at the part number on the tube). Installation and Operation Manual - Escape 1200 Page 27...
Mobile Home Installation THE IMAGES SHOWN ARE INDICATIVE ONLY AND MAY DIFFER OF YOUR PRODUCT, BUT THE ASSEMBLY REMAINS THE SAME. Screw the base on the floor with the proper hardware (O). Page 28 Installation and Operation Manual - Escape 1200...
Reinstall the glass, being careful to centre the glass in the door and not to over-tightening the retaining screw. The two main causes of broken door glass are uneven placement in the door and over-tightening the retaining screws. Installation and Operation Manual - Escape 1200 Page 29...
Remove the split pin by pulling and turning it using pliers. Turn the handle one counterclockwise turn to increase pressure. Reinstall the split pin with a small hammer. Figure 15: Removing the split pin Figure 16: Installing the split pin Page 30 Installation and Operation Manual - Escape 1200...
Using a flat screwdriver, turn the adjustable hinge rods in the direction shown to adjust the doors. Tighten all door hinge pressure screws when they are at the desired positions. Configurations 1-2-3-4-5-6, show in which direction these act on the adjustment of the door. Installation and Operation Manual - Escape 1200 Page 31...
Leave about ½" long of the gasket when cutting and press the end into the groove. Tuck any loose fibers under the gasket and into the silicone. Close the door. Do not use the stove for 24 hours. Page 32 Installation and Operation Manual - Escape 1200...
8. Exploded Diagram and Parts List Installation and Operation Manual - Escape 1200 Page 33...
Page 34
ESCAPE 1200 CAST IRON DOOR ASSEMBLY AC06500 SILICONE AND 5/8" X 8' BLACK DOOR GASKET KIT AC01420 RIGID FIRESCREEN PL06728 PAINTED AIR CONTROL HANDLE 30129 METAL SCREW #10 X 1/2" PAN QUADREX ZINC "A" TYPE Page 34 Installation and Operation Manual - Escape 1200...
Page 35
LEVELING BOLT 1/4 - 20 X 1'' 30185 17/64" AA TYPE WASHER BLACK 30100 BLACK HEX NUT 1/4 - 20 SE74266 ESCAPE 1200 PEDESTAL ASSEMBLY PL74268 BACK OF THE BASE SE74362 ESCAPE 1200 GLASS AND MOLDING KIT Installation and Operation Manual - Escape 1200 Page 35...
Shall your unit or a component be defective, contact immediately your DROLET dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling: •...
Page 38
Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002 of information contained in any document obtained from https://www.drolet.ca/en/ unauthorized sources. tech@sbi-international.com...