3.1.2
With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
20" (5078 mm)
C
14" (356 mm)
L
70" (1778 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
8" (203 mm)
B
20" (508 mm)
C
12" (305 mm)
L
70" (1778 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
1
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
28 ¾" (730 mm)
F
23 ¾" (603 mm)
1
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.
Page 16
USA
14 ½" (368 mm)
20" (5078 mm)
14" (356 mm)
70" (1778 mm)
USA
8" (203 mm)
20" (508 mm)
12" (305 mm)
70" (1778 mm)
FROM PIPE CONNECTOR
USA
18" (457 mm)
28 ¾" (730 mm)
23 ¾" (603 mm)
Ve
Ho
DISTANCES
FROM PIPE CONNECTOR
1
WITH DOUBLE WALL PIPE CONNECTOR
Canada
11 ½" (292 mm)
D
E
28 ¾" (730 mm)
F
21 ¾" (552 mm)
Installation and Operation Requirements - Black Stag II
L
USA
11 ½" (292 mm)
28 ¾" (730 mm)
21 ¾" (552 mm)