3.5 Pet Mask Mounting (optional)
For pet immunity (up to 18Kg/40lb), a special "pet mask" model PET 10/12 should
be mounted on the mirror (see figure 6, step 4a).
3.6 Test
A. Power up the system. The LEDs will flash alternately, indicating that the
detector is adapting itself to its present surroundings. Stay at least 1m (3ft)
away from the detector, until the 60 seconds startup period ends (until
the LEDs stop flashing alternately).
B. Enter the detector's field of view and perform walk test in the entire
coverage area, while observing the red LED (see figure 2). For TOWER 12,
observe also the green LED for MW and PIR detections (see "LED
indications" table in the specifications). The red LED will light for 2-3
seconds each time the alarm output is activated (see figure 2).
Important! Instruct the user to perform walk test at least once a week to
verify proper operation of the detector.
C. Tape a piece of cardboard to the detector's front to deliberately mask the
optical window. After 30 seconds, the yellow LED should light (the TRB
relay drops out).
D. Remove the masking from the detector's front. The yellow LED should
extinguish (after a few seconds).
4. SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated or may fail to warn
due to: DC power failure / improper connection, tampering with the optical system,
decreased sensitivity in ambient temperatures close to that of the human body and
unexpected failure of a component part.
ESPAÑOL
1. INTRODUCCIÓN
TOWER 10 AM PIR y TOWER 12 AM Doble Tecnología, son detectores
profesionales anti-vandálicos y Anti-Masking, diseñados para su utilización en
comercios e industria, proporcionando una gran cobertura así como una mayor
resistencia en entornos agresivos, gracias al empleo de varias tecnologías
. Ambos
revolucionarias, patentadas
Grado 3.
Características:
• Tecnología V-slot con ventana reducida (patente pendiente) aportando una
mayor Resistencia mecánica y protección ante falsas alarmas (patente
pendiente).
• Tecnología basada en "Obsidian Black Mirrors"™ y diseño de espejo " Elíptico
/ Parabólico" proporcionando Resistencia a luz Blanca de mas de 15,000 LUX
y una cortina múltiple-sólida que proporciona una respuesta en sensibilidad
mejor del 50% comparada con otras ópticas de espejo (varias patentes
pendientes).
• Tecnología Anti-Masking mediante Infra-Rojos Activos, proporciona la mas
avanzada protección frente intentos de enmascaramiento (patente pendiente).
• Espejo Opcional intercambiable, Cortina Largo Alcance con una cobertura de
35 m x 2,5 m (115 ft x 8,2 ft) para el TOWER-10 y 25 m x 2 m (82 ft x 6,5 ft)
para el TOWER-12.
• Mejoras para el instalador:
Módulo interno para selección de resistencias final de línea E.O.L. para salidas
de alarma, problema y tamper.
Terminales tipo Plug-in para una más fácil instalación del precableado.
Sistema de cierre mediante deslizamiento con un tornillo imperdible.
Montaje extendido en altura 1,5 m – 4 m (5 ft – 13 ft).
Indicación de bajo valor de tensión de alimentación.
Entrada de Test de paseo controlada remotamente.
Soportes de montaje opcionales.
Área de protección ajustable mediante Selector de Rango (TOWER 12 AM).
• Control por Microprocesador, procesamiento de señal digital TMR con
compensación de temperatura digital de doble pendiente.
• Tamper Frontal y posterior.
• Verdadera "Creep zone" óptica ángulo cero.
• Inmunidad a mascotas (18Kg/40lb) usando un filtro especial "pet mask".
• Auto diagnóstico para ambos detectores PIR y Microondas.

2. ESPECIFICACIONES

OPTICA
Cobertura
25mx30m / 90º
Campo Alejado (FOV)
Medio Campo (FOV)
Posición Cont. eventos
Montaje:
Tipo: Superficie, esquina ó a 45º sobre pared.
Altura: 1,5 m – 4 m (5 ft. – 13 ft.) sin soporte.
Ajuste Vertical: Proporciona tres ajustes verticales dependiendo de la altura
de instalación y rango de cobertura.
2
detectores son conformes con EN 50131
Tipos de espejo (ver Fig. 2)
Gran Angular
Cort. Largo Alcance
TOWER 10 & 12
TOWER 10
TOWER 12
35m / 5º
11 cortinas
1 cortina
6 cortinas
1 cortina
1 ó 2
LR
The above list includes the most common reasons for failure to detect intrusion, but is
by no means comprehensive. It is therefore recommended that the detector and the
entire alarm system be checked weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home and
property owners or renters should be prudent enough to continue insuring their lives
and property, even though they are protected by an alarm system.
This device has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in residential installations. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio and television reception. However, there is no guarantee that
interference will not occur in a particular installation. If this device does cause such
interference, which can be verified by turning the device off and on, the user is
encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from
which you orignially purchased it. If you are discarding this product and not returning it for
repair then you must ensure that it is returned as identified by your supplier. This product is
not to be thrown away with everyday waste.
Directive 2012/19/EC Waste Electrical and Electronic Equipment.
ELECTRICAS
Tipo Sensores:
PIR: sensor piro-eléctrico de elemento dual y bajo ruido.
MW: Módulo Doppler en Banda X.
Para UK – 10,587 GHz, para EU / USA – 10,525 GHz. Para
German/Czech 9,35 GHz
Potencia máxima de radiofrecuencia: 27 dBm @ 10,525 GHz and 10,587 GHz
Tensión de Alimentación: 8 – 16 VDC.
NOTA: La unidad estará alimentado sólo por fuente de alimentación limitada
(marcado" LPS ") fuente de alimentación certificada.
Detección de Baja tensión: Si la tensión es inferior a 7,5 VDC.
Corriente de Alimentación:
Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12).
Máximo: 14mA (TOWER 10 AM). 18 mA (TOWER 12).
PRECAUCIÓN: La unidad debe alimentarse desde un panel de control
certificado con un voltaje nominal de 8-16 VDC y que tenga una salida de
suministro CP que esté limitada por un fusible de acción rápida de 0,5A o
0,75A.
Periodo Alarma: 2 a 3 seg.
Retardo detección de Masking: 30 seg.
Entrada para activación remota de LED (TST): Alta Impedancia. Afecta a los
LEDs de operación solo si el selector interno de LED esta en la posición OFF.
Salidas:
Salida Alarma: Relé Estado Sólido . NC, 100 mA / 30 V, resistencia interna
máxima 35. "Abierto" durante 2 – 3 seg. en caso de alarma, masking ó fallo
total de alimentación.
Salida Problema: Relé Estado Sólido. NC, 100 mA / 30 VDC, resistencia
interna máxima 35 ohm. "Abierto" en caso de fallo auto-diagnóstico, evento
Anti-Mask, bajo voltaje ó fallo completo de alimentación.
Salida Tamper: NC, 50mA / 30 VDC. "Abierto" al abrir la tapa del detector ó
al desprenderlo de la superficie de montaje.
Incluye Circuito de Resistencias Final de Línea: Selección de tabla de
resistencias serie para cada una de las tres salidas. Valores Resistivos: 0 Ohm
(Selecc. Fábrica), 1 K, 2,2 K, 4,7 K, 5,6 KOhm (ver fig. 5).
Indicaciones de los LEDs:
Evento / status
Baja tensión
Sobre-Temp.
(60sec.)
Fallo Auto-test
Detección AM
ALARMA
Detecc. PIR
Detecc. MW
25m / 5º
Tiempo Sobre-Temperatura: 60 sec.
MEDIOAMBIENTALES
Temperatura Operación: -20°C a 55°C (-4°F a 131°F).
Temperatura Almacenaje: -20°C a 60°C (-4°F a 140°F)
Protección RFI: Mejor de 20 V/m (hasta 2 GHz).
Protección caja: IP41 y IK04 .
Dimensiones: 160x77x47mm (6-5/16 x 3 x 1-13/16 in.)
ACCESSORIOS Opcionales:
D-300909 TOWER 10 AM/TOWER 12 AM Installation Instructions
14 dBm @ 9,35 GHz
Indicación
TOWER 12 AM
TOWER 10 AM
Rojo parpadeando
Amarillo + Rojo + Verde
Amarillo+ Rojo
parpadean alternat.
parpadean alternat.
Amarillo + Rojo parpadean alternativamente
Amarillo ON
Rojo ON
Verde parpadeando
Verde ON
---
---

Advertisement

loading

This manual is also suitable for:

Visonic tower 12 am