Electrical Adjustment Instructions - FUNAI 26FL532/10 Service Manual

Hide thumbs Also See for 26FL532/10:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note: "CBA" is abbreviation for
"Circuit Board Assembly."
Note: Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. Remote control unit
2. Color Analyzer,
CA-310 (KONICA MINOLTA Luminance meter) or
measuring instrument as good as CA-310.
How to set up the service mode:
Service mode:
1. Turn the power on.
2. Press [SOURCE], [2], [5], [8] and [0] buttons on
the remote control unit in this order to enter the
service mode. The Factory Setting menu appears
in the screen.
Example:
5-1
LC10P(A23F0EP)EA