The gas connection to the appliance is effected by means of a suitable
Ÿ Ÿ
coupling tube fitting L8, DIN 2353-ST, complying with European Standard
EN 1949 (e.g. Ermeto).
The gas connection may only be carried out by a qualified personnel.
SW 17
The refrigerator must be equipped with a
gas cock (C) in the supply line to allow the
supply to be disconnected. Such a cutout
device must be readily accessible to the user.
Gas-pressure
Category
I
3P(30)
mbar
30
BE
DK
DE
FI
FR
GR
IE
IS
IT
LU
X
NL
X
NO
AT
PT
SE
CH
ES
UK
SW 14
Following proper installation, a testing for
leakage and a flame test must be carried out
by *qualified personnel in compliance with
EN1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts
who are able, by virtue of their training
and knowledge, to vouch for the correct
implementation of the leakage test.
I
I
3P(50)
3P(37)
37
50
X
X
X
24
C
I
I
3+
3B/P(50)
28-37
30-37
X
X
X
X
X
X
X
X
X
I
3B/P(30)
50
30
X
X
X
X
X
X
X
X
X
X
X
X
X
X