Gas Installation - Dometic RM 6270 Manual

Hide thumbs Also See for RM 6270:
Table of Contents

Advertisement

6.7.2
Separate fume extraction
3. Insert flue pipe (C) through the aperture.
4. Connect flue pipe (C) to T-piece (E). If necessary, shorten flue pipe (C) to the
required length.
5. Pack the cut with non-flammable material (e.g. Rock Wool).
6. Screw securing plate (D) into position.
7. Put cap (B) on flue pipe (C).
8. Screw on outer plate (A).
6.8

Gas installation

The rules in point 6.1 must be adhered to.
Ÿ
When running on gas, these appliances are intended exclusively to use
Ÿ Ÿ
liquid gas (propane/butane) - under no circumstances should town gas or
natural gas be used (EN 27418).
A fixed, pre-set pressure regulator complying with EN 12864 must be
Ÿ Ÿ
connected to the liquid gas cylinder.
The pressure regulator must concur with the operating pressure specified
Ÿ Ÿ
on the data plate of the appliance. The operating pressure corresponds to
the standard pressure of the country of specification (EN 1949, EN 732).
Only one connection pressure is permissible for any one vehicle. A plate
Ÿ Ÿ
showing the permanent, clearly legible notice must be displayed in full view
at the point where the gas cylinder is installed.
The gas connection to the appliance must be installed securely and at
Ÿ Ÿ
zero potential using tube connectors and must be securely connected to the
vehicle (a hose connection is not permissible) (EN 1949).
Inflamable material should not be in immediate proximity to the burner.
Ÿ Ÿ
Cut:
80mm high
40mm wide
1. Cut an 80mm x 40mm rectangle in the outer
wall of the caravan. The position of the cut
must be appropriate to the particular model
of refrigerator and installation conditions.
2. Connect T-piece (E) to adaptor (F) or flue
pipe (K) as required and affix with screw
(G). Ensure that heat distributor (H) is
lodged in the correct position.
23
min. 10 mm
max. 20 mm

Advertisement

Table of Contents
loading

Table of Contents