Panasonic EverVolt EVPV HK Series General Installation Manual page 14

Table of Contents

Advertisement

INSTALLATION OF EVPVXXXH AND EVPVXXXHK SERIES MODULES
MOUNTING EVPVXXXH AND EVPVXXXHK SERIES MODULES WITH CONTINOUS RAILS PARALLEL
TO SHORT SIDE OF THE MODULE
A continous rail (or other support structure) spans the complete underside of the module.
0
10.0 in [255 mm]
Figure 12. Clamping of EVPVxxxH and EVPVxxxHK Series modules with rails parallel to short side of the module
Legend
Clamping zone
Rail position
Rail position
Once a module is secured in each of the 4 zones (Figure 8.), additional clamps, i.e., ≥5, may be freely located on panel
frame without affecting the warranty. Loads marked with a * were not certified as part of UL 61730 testing; these have been
evaluated by internal testing process.
**Gap between the uppermost part of the installation surface(e.g. rooftop) and the lowest part of the panel (i.e. underside of panel frame)
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to
be rated to that load (Figure 12.).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
General Installation Manual
27.5 in [700 mm]
24.0 in [610 mm]
19.9 in [505 mm]
14.8 in [375 mm]
0.8 - 1.6 in (20-40 mm)
Clearance Gap
**
(Design Load)
0 - 10.0 in
(0 - 255 mm)
10.0 - 14.8 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(255 - 375 mm)
14.8 - 19.9 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(375 - 505 mm)
15.9 - 24.0 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(505 - 610 mm)
24.0 - 27.5 in
+2400 Pa / -2400 Pa *
(+1600 Pa / -1600 Pa)
(610 - 700 mm)
0 - 7.9 in
(0 - 200 mm)
7.9 - 11.8 in
(200 - 300 mm)
27.5 in [700 mm]
24.0 in [610 mm]
19.9 in [505 mm]
1.6 - 2.4 in (40-60 mm)
Test Load
Test Load
(Design Load)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+4200 Pa / -2400 Pa
(+2800 Pa / -1600 Pa)
+6200 Pa / -4000 Pa
(+4133 Pa / -2666 Pa)
+3000 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+800 Pa / -800 Pa *
X
(+533 Pa / -533 Pa)
0
14.8 in [375 mm]
10.0 in [255 mm]
>2.4 in (>60 mm)
<0.8 in (<20 mm)
Test Load
(Design Load)
+2400 Pa / -2400 Pa *
(+1600 Pa / -1600 Pa)
+5400 Pa / -2400 Pa
(+3600 Pa / -1600 Pa)
+7000 Pa / -4000 Pa
(+4666 Pa / -2666 Pa)
+5400 Pa / -2400 Pa
(+3600 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
Test Load
(Design Load)
X
X
X
X
X
X
X
13