Panasonic EverVolt EVPV HK Series General Installation Manual page 13

Table of Contents

Advertisement

MOUNTING EVPVXXX AND EVPVXXXK SERIES WITH SHORT RAILS
A short rail is a rail with a min. length of 2 in (50 mm) that does not span the complete underside of a module.
Figure 11. Clamping of EVPVxxx and EVPVxxxK Series modules using short rails
Legend
Clamping zone
Rail length under
module
1 - 4 in
Rail length under
module
4 - 7.9 in
Once a module is secured in each of the 4 zones (Figure 8), additional clamps, i.e., ≥5 may be freely located on panel frame
without affecting the warranty. Loads marked with a
evaluated by internal testing process.
**Gap between the uppermost part of the installation surface(e.g. rooftop) and the lowest part of the panel (i.e. underside of panel frame)
General Installation Manual
27.4 in [695 mm]
0
23.8 in [605 mm]
22.2 in [565 mm]
13.4 in [340 mm]
8.2 in [208 mm]
0.8 - 1.6 in (20-40 mm)
Clearance Gap
**
Test Load
(Design Load)
0 - 8.2 in
X
(0 - 208 mm)
8.2 - 13.4 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(208 - 340 mm)
13.4 - 22.2 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(340 - 565 mm)
22.2 - 23.8 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(565 - 605 mm)
23.8 - 27.4 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(605 - 695 mm)
0 - 4 in
X
(0 - 100 mm)
4 - 9.8 in
X
(100 - 250 mm)
0 - 8.2 in
X
(0 - 208 mm)
8.2 - 13.4 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(208 - 340 mm)
13.4 - 22.2 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(340 - 565 mm)
22.2 - 23.8 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(565 - 605 mm)
23.8 - 27.4 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(605 - 695 mm)
0 - 4 in
X
(0 - 100 mm)
4 - 9.8 in
X
(100 - 250 mm)
27.4 in [695 mm]
23.8 in [605 mm]
22.2 in [565 mm]
13.4 in [340 mm]
8.2 in [208 mm]
1.6 - 2.4 in (40-60 mm)
Test Load
(Design Load)
+1200 Pa / -1200 Pa *
+1600 Pa / -1600 Pa *
(+800 Pa / -800 Pa)
(+1066 Pa / -1066 Pa)
+4100 Pa / -2400 Pa
+4500 Pa / -2400 Pa
(+2733 Pa / -1600 Pa)
(+3000 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
+4200 Pa / -4000 Pa
(+2000 Pa / -2000 Pa)
(+2800 Pa / -2666 Pa)
+2400 Pa / -2400 Pa
+3600 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
(+2400 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
+1600 Pa / -1600 Pa *
(+800 Pa / -800 Pa)
(+1066 Pa / -1066 Pa)
+800 Pa / -800 Pa *
+2400 Pa / -2400 Pa
(+533 Pa / -533 Pa)
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
+1600 Pa / -1600 Pa *
(+800 Pa / -800 Pa)
(+1066 Pa / -1066 Pa)
+3600 Pa / -2400 Pa
+3600 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
(+2400 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
+3000 Pa / -3000 Pa
(+2000 Pa / -2000 Pa)
(+2000 Pa / -2000 Pa)
+2400 Pa / -2400 Pa
+3600 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
(+2400 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
+1600 Pa / -1600 Pa *
(+800 Pa / -800 Pa)
(+1066 Pa / -1066 Pa)
+800 Pa / -800 Pa *
+2400 Pa / -2400 Pa
(+533 Pa / -533 Pa)
(+1600 Pa / -1600 Pa)
*
were not certified as part of UL 61730 testing; these have been
0
>2.4 in (>60 mm)
<0.8 in (<20 mm)
Test Load
Test Load
(Design Load)
(Design Load)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
12

Advertisement

Table of Contents
loading

Table of Contents