Panasonic EverVolt EVPV HK Series General Installation Manual page 19

Table of Contents

Advertisement

MOUNTING EVPXXXXPK SERIES MODULES WITH SHORT RAILS
A short rail (or other short support structure) has a minimum length of 25 mm and does not span the complete underside
of a module.
Figure 17. Clamping of EVPVxxxPK Series modules using short rails
Legend
Clamping zone
Rail length under
module
1 - 3.9 in
(25 - 100 mm)
Rail length under
module
3.9 - 7.9 in
(100 - 200 mm)
Once a module is secured in each of the 4 zones (Figure 8), additional clamps, i.e., ≥5 may be freely located on panel frame
without affecting the warranty. Loads marked with a
evaluated by internal testing process.
**Gap between the uppermost part of the installation surface(e.g. rooftop) and the lowest part of the panel (i.e. underside of panel frame)
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be rated
to that load (Figure 17). If the panel is secured in zones with different load values, it is rated to the lowest load value only.
General Installation Manual
28.0 in [712 mm]
0
24.5 in [622 mm]
22.9 in [582 mm]
14.1 in [357 mm]
8.9 in [225 mm]
0.8 - 1.6 in (20-40 mm)
Clearance Gap
**
Test Load
(Design Load)
0 - 8.9 in
(0 - 225 mm)
8.9 - 14.1 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(225 - 357 mm)
14.1 - 22.9 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(357 - 582 mm)
22.9 - 24.5 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(582 - 622 mm)
24.5 - 28.0 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(622 - 712 mm)
0 - 4 in
(0 - 100 mm)
4 - 9.8 in
(100 - 250 mm)
0 - 8.9 in
(0 - 225 mm)
8.9 - 14.1 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(225 - 357 mm)
14.1 - 22.9 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(357 - 582 mm)
22.9 - 24.5 in
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
(582 - 622 mm)
24.5 - 28.0 in
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
(622 - 712 mm)
0 - 4 in
(0 - 100 mm)
4 - 9.8 in
(100 - 250 mm)
28.0 in [712 mm]
24.5 in [622 mm]
22.9 in [582 mm]
14.1 in [357 mm]
8.9 in [225 mm]
1.6 - 2.4 in (40-60 mm)
Test Load
(Design Load)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+4100 Pa / -2400 Pa
(+2733 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
(+2000 Pa / -2000 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+800 Pa / -800 Pa *
X
(+533 Pa / -533 Pa)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+3600 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
(+2000 Pa / -2000 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1200 Pa / -1200 Pa *
X
(+800 Pa / -800 Pa)
+800 Pa / -800 Pa *
X
(+533 Pa / -533 Pa)
*
were not certified as part of UL 61730 testing; these have been
0
>2.4 in (>60 mm)
<0.8 in (<20 mm)
Test Load
Test Load
(Design Load)
(Design Load)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+4500 Pa / -2400 Pa
(+3000 Pa / -1600 Pa)
+4200 Pa / -4000 Pa
(+2800 Pa / -2666 Pa)
+3600 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+3600 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
(+2000 Pa / -2000 Pa)
+3600 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
18