(#SCAN> FEEDER> FUNCTION> FAN-ON)
Starting the fan operation.
Selecting 1 starts fan operation.
(#SCAN> FEEDER> FUNCTION> SL-CHK)
Checking the ADF solenoid.
Specify a solenoid to perform a solenoid check. Select #SCAN>FEEDER > FUNCTION > SL-
ON to execute this.
0: Pressure solenoid (SL1)
1: Stamp solenoid (SL2)
(#SCAN> FEEDER> FUNCTION> MTR-ON)
Starting the motor operation.
Selecting 1 start motor operation.
(#SCAN> FEEDER> FUNCTION> ROLL-ON)
ADF roller cleaning mode.
Rotate the roller with the motor and attach a lint-free paper moistened with alcohol to the
roller to clean it.
(#SCAN> FEEDER> FUNCTION> FEED-ON)
Checking the passage of paper with ADF.
Selecting 1 starts checking passage of paper by the ADF.
All manuals and user guides at all-guides.com
#PRINT

Numerin Parameter Settings (Numeric Prama).

Item
#PRINT
NUMERIC
#PRINT
NUMERIC
No.
Default
Setting range
Function
SW01- SW13
Not used
SW14:
00000100
Special mode setting
SW15: -
Not used
SW17:
SW18:
00000100
Special mode setting
SW19: - 50:
Not used
01: - 30:
Not used
34:
100
'-128 to 127, one
Left-end registration adjustment (manual
unit = 0.1 mm
feed tray)
35:
100
'-128 to 127, one
Left-end registration adjustment (cassette 1)
unit = 0.1 mm
36:
100
'-128 to 127, one
Left-end registration adjustment (cassette 2)
unit = 0.1 mm
37:
100
'-128 to 127, one
Left-end registration adjustment (cassette 3)
unit = 0.1 mm
38:
100
'-128 to 127, one
Left-end registration adjustment (cassette 4)
unit = 0.1 mm
39: - 52:
Not used
53:
25
0 to 9999, one
Adjustment of margin at leading edge of
unit = 0.1 mm
copy
54:
25
0 to 9999, one
Adjustment of margin at trailing edge of
unit = 0.1 mm
copy
55:
25
0 to 9999, one
Adjustment of margin at right edge of copy
unit = 0.1 mm
56:
25
0 to 9999, one
Adjustment of margin at left edge of copy
unit = 0.1 mm
57:
Not used
58:
145
'-128 to 127, one
Adjustment of the registration loop volume
unit = 0.1 mm
(Manual tray)
59:
163
'-128 to 127, one
Adjustment of the registration loop volume
unit = 0.1 mm
(Cassette)
60:
Not used
61:
145
'-128 to 127, one
Adjustment of the registration loop volume
unit = 0.1 mm
(Duplex unit)
62:
7
0 to 14
Temperature adjustment UP/DOWN mode
(For normal paper)
63:
7
0 to 14
Temperature adjustment UP/DOWN mode.
(For thick paper)
64:
2
0 to 4
Mode for preventing the end temperature
rise
65:
0
0 to 2
Mode for reducing sand image
66:
0
0 to 3
Temperature/ Humidity sensor fixed mode
67:- 135:
Not used
136:
1000
'-512 to 512
Adjustment of the point to start writing in
main scanning direction (A)
137:- 139:
Not used
140:
100
'-128 to 127, one
Left-end registration adjustment (double-
unit = 0.1 mm
sided small)