Masonry Fireplace Installation - Freestanding; Mobile Home Installation - Vistaflame VF1200 Owner's Manual

Table of Contents

Advertisement

m
F
i
AsonrY
ireplACe
Rain Cap
Chimney
Support and Clamp
Rigid Stainless
Steel Liner
Listed Liner
Stove pipe must
end higher than liner
Flexible Stainless
Steel Section
Clean-out tee
Clean-out
cover
Figure 35: Freestanding Installation into existing fireplace.
m
H
i
oBile
ome
nstAllAtion
SPECIAL REQUIREMENTS: Pedestal models 1200 and 1700 are approved for mobile homes. A 1200
or 1700 Insert may also be installed into a Mobile Home in the U.S. provided there is a Mobile Home
approved Factory Built Fireplace installed with adequate fresh air supply, and that that Factory Built
Fireplace is not altered beyond the damper or ash shelf being modified. In Canada, Insert Mobile Home
installations must be pre-approved by the local inspector. All freestanding installation requirements in
" Installation Of A Listed, Factory Built Chimne y", must comply with all local codes that may apply, and
the following must be met:
VENTING:
In Canada: Any ULC-S629 listed chimney system with the accompanying double-wall vent connector.
In U.S.A. Any UL-103-HT listed chimney system with the accompanying double-wall vent connector.
Do not connect a listed chimney of one manufacture with a listed double wall connector from another
manufacture.
Installation
- F
nstAllAtion
reestAnding
Steel Plate or Flashing
Masonry Fireplace
:
:
Unless you are experienced, we recommend
installation by your dealer or a professional
installer.
Many venting manufacturers have listed kits
available to connect a stove to a masonry fireplace.
Always follow the vent manufacturer's installation
instructions.
The existing damper may have to be
removed to allow installation.
Damper Removed
or Fastened Open
Stainless Steel
Connector Pipe
Floor Protection
Combustible Floor
33