SECTION 7
COUPLING
Rotating machinery can cause personal injury or death. Turn the unit
completely off, open the main disconnect, lockout and tagout before servicing
the coupling.
COUPLING - The motor and compressor are direct connected by a resilient type flexible coupling with a
single cushion. The coupling does not require lubrication.
If maintenance on mating parts is required, reassemble coupling as follows:
Figure 7-1 – INSTALLATION OF COUPLING CUSHIONS