Section 7, Coupling; Figure 7-1 - Installation Of Coupling Cushions - Gardner Denver AUTOSENTRY EAQ99Q Operating And Service Manual

Electra-saver electra-saver ii stationary base-mounted compressor
Table of Contents

Advertisement

SECTION 7
COUPLING
Rotating machinery can cause personal injury or death. Turn the unit
completely off, open the main disconnect, lockout and tagout before servicing
the coupling.
COUPLING - The motor and compressor are direct connected by a resilient type flexible coupling with a
single cushion. The coupling does not require lubrication.
If maintenance on mating parts is required, reassemble coupling as follows:
Figure 7-1 – INSTALLATION OF COUPLING CUSHIONS
13-9-666
Page 65

Advertisement

Table of Contents
loading

Table of Contents