Gardner Denver EAQ99T Operating And Service Manual page 19

Table of Contents

Advertisement

DISCHARGE SERVICE LINE - The discharge service line connection on both water-cooled and air-
cooled units is made at the right hand corner of the unit, viewed from the opposite end from control panel
side. When connecting two or more GD rotary screw units on a common manifold, each unit is isolated
by the check valve in the unit discharge line. If a Gardner Denver rotary screw unit is connected to
another compressor on a common manifold be sure the other compressor has a check valve in the line
between the machine and the manifold. If a rotary screw and a reciprocating compressor are connected
together on a common manifold, an air receiver must be located between the two units.
Discharge air used for breathing will cause severe injury or death.
Consult filtration specialists for additional filtration and treatment equipment to
meet health and safety standards.
BLOWDOWN VALVE PIPING -
and air filter.
HP
Model
125 HP
EAQ99T
125 HP
EBQ99P
150 HP
EAQ99T
150 HP
EBQ99P
200 HP
EAQ99T
200 HP
EAU99U
200 HP
EBU99E
200 HP
EBQ99P
* 80° F Maximum Water Temperature when aftercooler & oil cooler are piped in series (std).
** Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
The blowdown valve is piped back into the airend between the inlet valve
HEAT EXCHANGER
Water Temperature to Heat
Exchanger
(gpm)
60° F
70° F
80° F
12.1
15.2
20.2
11.3
14.1
18.9
14.6
18.2
24.3
13.1
16.3
21.8
18.3
22.8
30.4
18.9
23.6
31.5
18.9
23.6
31.5
16.4
20.4
27.3
13-21-602
Maximum
Water Flow
(gpm) **
90° F
30.3
40.0
28.3
40.0
36.4
40.0
32.7
40.0
45.5
110.0
47.3
110.0
47.3
110.0
40.9
110.0
Page 18
Approximate Water
Pressure Drop @ 90° F
Water Temperature
(psi)
4.0
4.0
4.0
4.5
5.0
5.0
5.0
5.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ebq99pEau99uEbu99e

Table of Contents