Serviceable Items; Firebox Door Hinge / Latch Bearing Adjustment; Firebox Door Seal - Central Boiler CLASSIC EDGE 960 TITANIUM HDX Owner's Manual

Outdoor wood furnace
Table of Contents

Advertisement

SERVICEABLE ITEMS

NOTE: These procedures should be performed by a qualified individual and in accordance
with any and all federal, state/provincial and local codes and regulations. When
performing work on an appliance observe all precautions in the literature, tags and labels
attached to the appliance and other safety precautions that may apply. When working
with electricity and electrical components, failure to follow precautions could result in
property damage, personal injury or death.
NOTE: If any of these items are under warranty, remember that the warranty covers only
the cost of the replacement part. Labor is not covered.
NOTE: Use only genuine Central Boiler parts and accessories if it ever becomes necessary
to replace any component on the outdoor furnace.

FIREBOX DOOR HINGE / LATCH BEARING ADJUSTMENT

If the firebox door seal has been replaced and it is not sealing properly, the
firebox door may need to be adjusted to close more tightly. When adjusting the
firebox door, make sure it is not adjusted too tightly as damage to the firebox
door, frame or door seal may result.
1.
To tighten the hinges, loosen the inner adjustment nut and turn the outer
nut in slightly; then tighten the inner adjustment nut securely. Adjust the
top and bottom hinge for equal pressure when the door is latched.
2.
To tighten the latch bearing, loosen the latch adjustment nut; then tap the
latch bearing assembly in toward the firebox. Tighten the latch adjustment
nut securely.
Hinge Adjustment Nuts

FIREBOX DOOR SEAL

The firebox door seal must be in good condition to ensure an airtight seal.
If the outdoor furnace is operated with the door open or ajar, the firebox
door seal may become damaged or brittle due to excessive temperatures. If
replacement is necessary, use the following procedure:
Remove all wood, coals and ash from the firebox.
1.
Disconnect power to the outdoor furnace.
CLASSIC EDGE OUTDOOR FURNACE • OWNER'S MANUAL
Latch
Adjustment
Nut
43

Advertisement

Table of Contents