Troubleshooting; General Troubleshooting Information - Central Boiler CLASSIC EDGE 960 TITANIUM HDX Owner's Manual

Outdoor wood furnace
Table of Contents

Advertisement

55
CLASSIC EDGE OUTDOOR FURNACE • OWNER'S MANUAL

TROUBLESHOOTING

GENERAL TROUBLESHOOTING INFORMATION

If the outdoor furnace is not operating the way it should, first review the
information found in the Operation Instructions section, particularly the
Adding Wood section.
INCORRECT
(Inadequate Flow)
Primary
Combustion
Air Inlets
Excessive
Coals
Restricted
Inadequate Flow
Ash
Is the Reaction Chamber full of ash?
The Reaction Chamber is where final combustion occurs. It is important that
the Reaction Chamber remain unobstructed to allow final combustion to
occur. It is not designed to be an ash collection area, although over time ash
will gradually accumulate in the Reaction Chamber.
If ash builds up in the Reaction Chamber to a level that obstructs flow, the
performance of the outdoor furnace will be affected, so the ash must be
removed. A good rule is to clean the Reaction Chamber before it becomes 1/2
full (approximately 5" or 13 cm deep in any area of the Reaction Chamber).