Function Setting
External Input/Output and Function Setting
Start of Setting
Turn ON DSW4-No.4.
Press PSW1 for at least3 seconds.
"Menu Mode" will be indicated.
End of Setting
Press PSW1 for at least 3 seconds.
The display indication become to
normal indication.
Turn OFF DSW4-No.4.
NOTE:
Release "Menu Mode" after the
setting is completed.
Otherwise, the air conditioner
may not operate properly.
[External Input and Output Setting]
1
By pressing the push-switches PSW3 ( )and PSW5
( ), the function No. can be selected.
PSW4 ( ): forward, PSW2 ( ): backward
Fill out the selected function setting No. in
the box of the table as shown on the right.
Item
SEG2
SEG1
Input Setting 1
1
CN17[1-2 pin]
Input Setting 2
2
CN17[2-3 pin]
Input Setting 3
3
CN18[1-2 pin]
Output Setting 1
4
CN16[1-2 pin]
Output Setting 2
5
CN16[1-3 pin]
(Setting before shipment)
Before shipping, the input/output function settings are
specified to each input/output terminal according to above table.
Setting External Input/Output Functions
Function
Input
No.
Fixing Heating Operation Mode
1
Fixing Cooling Operation Mo de
2
3
Demand Stoppage
4
Outdoor Fan Motor Start/Stop
5
Forced Stoppage
6
Demand Current Control 40%
7
Demand Current Control 60%
8
Demand Current Control 70%
9
Demand Current Control 80%
Demand Current Control 100%
10
11
Low Noise Setting 1
12
Low Noise Setting 2
13
Low Noise Setting 3
0
No set
The same input/output function setting can not be set to
different input/output terminals.
If set, a setting of larger function number is became invalid.
Press PSW1 once.
Menu Mode
For more details,
Check Mode
refer to "Checking of
"
"
Outdoor Unit by PCB"
in the Service Manual.
External Input and
Output
For the setting mode,
"
"
refer to ① below.
Function Setting
For the function setting,
"
"
refer to ② below.
Function Setting
2
By pressing the push-switches PSW3 (
PSW4 (
): forward, PSW2 (
<Example>
Refer to the Technical Catalog for more details.
Fill out the selected function setting No. in the
space of the table as shown.
SET
Item
Fan Intermittent Operation
1
during Heating Thermo-OFF
2 Night-Shift
Cancellation of Outdoor
3
Ambient Temperature Limit
Defrost for Cold Area
4
(Change of Defrost Condition)
SLo (Fan Speed)
5
Defrost Setting
6 Cancellation of Hot Start
7 Priority Capacity Mode
Frequency Control
(Control Target Value for
8
Cooling Compressor)
Output
Frequency Control
(Control Target Value for
9
Heating)
Indoor Expansion Valve
Warning signal
(Control Target Value for
10
Compressor ON Signal
Cooling)
frost Signal
Indoor Expansion Valve
(Control Target Value for
11
-
Heating)
-
Indoor Expansion Valve
(Opening during Heating
-
12
Operation Stoppage)
-
Indoor Expansion Valve
-
Opening during Heating
13
Thermo-OFF
-
Indoor Expansion Valve
-
Initial Opening during Heating
14
Thermo-ON
-
-
Indoor Expansion Valve
15
Initial Opening for Cooling
No set
Outdoor Expansion Valve
16
Initial Opening for Heating
Note:
(1) The function setting of "n3" must be set to correct value according to the quantity of water module connected,
otherwise, ALARM 37 may be triggered. (For example, in case of the quantity of water module in a system is
three, then the value of "n3" should be set to " ". )
(2) The function setting of "H4" must be set to correct value according to the type of water module connected:
H4=0 (default) : water module should be used in a three pipes heat recovery system.
H4=2: water module should be used in a two pipes heat pump system.
(2)The function setting of "Ui" can be set according to application requirement:
Ui=0 (default) : performance balance between indoor unit and water module.
Ui=1: indoor unit has priority on performance.
27
Arrangement of Dip
Switch Setting
SEG2
SEG1
PSW2
PSW5
PSW1
PSW3
PSW4
DSW1
DSW2
DSW3
DSW4
DSW6
DSW5
DSW8
DSW7
) and PSW5 (
), the setting can be changed.
): backward
Example
SEG2
SEG1
SET
Item
17 Sound Reduced Function
18 Demand Function Setting
19 Wave Function Setting
Protection of Decrease in
20
Outlet Temperature for Cooling
21 Reserved
Adjustment of Fan Rotation
22
(for multiple installation)
Min. Indoor Exp-Valve
Opening Setting at Heating
23
Functions SW-OFF
24 Snow Model Setting
25 Indoor VIP Function
26 Automatic Night-Shift
Height Difference
27
Setting
Economic Fuction
28
Setting
Quantity of Water
29
Module Connected
30 Type of Water Module
Performance Balance
31
between Indoor Unit and
Water Module
DSW10
SEG2
SEG1
SET