INDICATOR UNIT
LSE-D16-AB
MANUAL
Safety regulations  Mounting
Schematics
Control elements  Technical data
Programming
Functionality
Factory settings
www.aps-systems.ch
page 02
page 03
page 04
page 05
page 09
page 10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LSE-D16-AB and is the answer not in the manual?

Questions and answers

Summary of Contents for APS LSE-D16-AB

  • Page 1 INDICATOR UNIT LSE-D16-AB MANUAL Safety regulations  Mounting page 02 Schematics page 03 Control elements  Technical data page 04 Programming page 05 Functionality page 09 Factory settings page 10 www.aps-systems.ch...
  • Page 2: Safety Regulations

    Safety regulations Before the installation of the LSE-D16 Indicator unit read these instructions carefully and completely. Improper handling can result in severe personal injury, substantial property damage or even death. Cleaning Before cleaning first disconnect the equipment from the mains. Do not use any liquid cleaner or corrosive agent but solely a dampened cloth.
  • Page 3 Schematics The functions of the outputs LT (Lamp test), LQ (Lamp acknowledgement) and HQ (Horn acknowledgement.) can be customised see page 9, output functions. The LAN connection is intended for parameterisation in the web interface, as well as firmware updates.
  • Page 4: Control Elements

    Control elements The following buttons are integrated in the front of the unit: Horn acknowl. The output 9, Horn acknowledgement is activated The output 10, Lamp acknowledgement is Lamp acknowl. activated All LEDs, the buzzer as well as the lamp test Lamp acknowl.
  • Page 5: Programming Levels

    Programming can be done either with the web interface or with the operating elements on the unit. The use of the web interface is described in a separate documentation. Download the documentation from the homepage: www.aps- systems.ch Using the controls in programming mode:...
  • Page 6 When the programming mode is activated, LSE-D16 indicator unti starts at the level 1. The levels can be changed in active programming mode using the HQ and LT navigation keys. If for example Level 2 is active on operating input 1, pushing the HQ keys switches the LSE-D16 indicator unit to level 1.
  • Page 7 Level 3 Signalisation: Power-LED blinking green LQ-LED blinking green Level 3 is used to set the following additional parameters: Green LED = DIP-Switch off Red LED = DIP-Switch on LED Status Function All inputs of group 1: Without switch-on delay All inputs of group 1: 5 seconds switch-on delay All inputs of group 1: 10 seconds switch-on delay All inputs of group 1: 60 seconds switch-on delay...
  • Page 8 Level 4 Signalisation: Power-LED blinking green LQ-LED blinking magenta In level 4, the LT output (terminal 8) can be switched to common output priority 2. As soon as at least one input of the group 1 is assigned to the common output priority 2, the function is activated.
  • Page 9: Indicator Unit

    Functionality Indicator unit The LEDs on the front of the unit are an image of the associated inputs. Output functions Basic function factory setting Alternative function Setting location HQ-Output active as long as HQ button is pressed LQ -Output active as long as Common output for Level 3 LQ button is pressed...
  • Page 10: Reset To Factory Settings

    The factory settings can be restored by pressing the three buttons HQ+LQ+LT simultaneously for at least 10 seconds. All previous settings are lost; resetting to the factory settings cannot be undone. 01.23 APS systems AG Neumatt 4 CH-4626 Niederbuchsiten Tel. +41 (0)62 517 88 33 Switzerland E-Mail: systems@aps-systems.ch...