  • Page 1 OPERATION-/FAULT INDICATOR LSE-D16-24-BS MANUAL Safety regulations  Mounting page 2 Schematics page 3 Control elements  Technical data page 4 Programming page 5 Functionality page 7 www.aps-systems.ch...
  • Page 2 Safety regulations Before the installation of the LSE-D16 Operation-/Fault indicator read these instructions carefully and completely. Improper handling can result in severe personal injury, substantial property damage or even death. Cleaning Before cleaning first disconnect the equipment from the mains. Do not use any liquid cleaner or corrosive agent but solely a dampened cloth.
  • Page 3 Schematics The outputs LT (Lamp test), LQ (Lamp ack.) and HQ (Horn ack.) are only enabled using a DC power supply. The LQ and HQ functions can be customised, see the Programming chapter. The outputs are designed as a current sink and are not potential-free. If potential-free contacts are required, a relay must be utilised.
  • Page 4 Control elements The following buttons are integrated in the front of the unit: The built-in buzzer and the horn output are Horn acknowl. deactivated. Lamp acknowl All queued alarms are acknowledged All LEDs as well as the lamp test output are Lamp acknowl.
  • Page 5 Programming General Using the controls in programming mode: Icon Designation Description Function in programming mode Horn Navigation up acknowledgement Alarm acknowledge Switch Lamp test Navigation down The programming mode is started as follows: Power up the unit and push the HQ and LT keys at the same time within 10 seconds.
  • Page 6 Level 1 Level 1 is used to set if the fault indicator inputs are a NO closing contact or a NC opening contact. The green flashing LED signals the selected fault indicator input. The LQ key is used to switch the function: ...
  • Page 7 Level 3 Level 3 is used to set the following additional parameters: Green LED = DIP-Switch off Red LED = DIP-Switch on LED Status Function All fault indicator inputs without switch-on delay All fault indicator inputs with 5s switch-on delay All fault indicator inputs with 10s switch-on delay All fault indicator inputs with 60s switch-on delay Inner buzzer on...
  • Page 8 Setting with DIP-Switch 7 - 10, see page 6. 08.20 APS systems AG Neumatt 4 CH-4626 Niederbuchsiten Tel. +41 (0)62 517 88 33 Switzerland E-Mail: systems@aps-systems.ch...