APS LSC Installation & User Manual

APS LSC Installation & User Manual

Annunciator system

Advertisement

Quick Links

APS
Annunciator System LSC
Installation & User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LSC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for APS LSC

  • Page 1 Annunciator System LSC Installation & User Manual...
  • Page 2: Table Of Contents

    Content Safety and installation..................3 Installation:..........................3 Fitting: ........................... 3 Supplementary power: ......................3 Wiring:........................... 3 Connection principle: ......................4 System features....................5 System components ..................5 System expansion capability................5 Installation ......................6 Setting the module ID-address: .................... 6 Factory settings:........................
  • Page 3: Safety And Installation

    Fitting: The BM Basic Module the RM Relay Module and the CIM Connector of the LSC System are fitted on top-hat mounting rails (DIN rails). The PM Panel Module is fitted into a control panel.
  • Page 4: Connection Principle

    Connection principle:...
  • Page 5: System Features

    System features Modular system: For the processing of new value/first-up value alarms in accordance with DIN 19235: o Building services and building automation o Control systems o Process automation o Power transmission, power distribution o Transport o Communication On-Delay: Individually On-delay setting for all in- and outputs up to 47 minutes Serial interface: For networking (BUS coupling)
  • Page 6: Installation

    (see Technical Data). Voltage which is too high or false polarity of the voltage can lead to damage of the LSC System. After switching on the voltage supply of the LSC System (system voltage) the green LED "POWER ON"...
  • Page 7: Factory Settings

    Warning: If you are using a single Basic Module BM the address has to be set to the stand alone mode (all LED are blinking) which is factory setting. Otherwise, a bus error will occur. Important: If you are in the module ID address setting process and do not press any button for six seconds, the module will switch back to operation mode without saving your changes.
  • Page 8: Can-Bus

    Failure neighbour module: The next module has lost it’s connection or does not work properly . Steady light flashing Important: After having successfully resolved a CAN-bus error, it is recommended to completely restart the LSC system by turning off an on again the supply voltage.
  • Page 9: Installation Check List

    Installation check list Checkpoint Module Connectors Installation Check Supply voltage Power supply Alarm voltage Power supply Supply voltage (connection) First Switch ON 1 Termination resistor Last Switch ON 1 Alarm inputs + 8-15 Alarm inputs - Horn acknowledgement + Horn acknowledgement - Lamp acknowledgement + Lamp acknowledgement - Lamp test +...
  • Page 10: Basic Module Bm

    Basic Module BM Application & Characteristics The BM Basic Module is the foundation stone of the modularly expandable LSC product family. The BM Basic Module is supplied in the installation housing for top-hat rail mounting. o 8 operation indicator o Integrated buzzer...
  • Page 11: Wiring Diagram

    Wiring diagram:...
  • Page 12: Relay Module Rm

    Relay Module RM Application & Characteristics The Relay Module RM provides 8 potential free contacts which could be used to build an external signalising or switch other devices. The BM Basic Module is supplied in the installation housing for top-hat rail mounting. o 8-channel relay module o Contact load carrying up to 250 VAC / 3 A per relay output o Normally open or normally closed current principles...
  • Page 13: Wiring Diagram

    Wiring diagram:...
  • Page 14: Panel Module Pm

    Panel Module PM Application & Characteristics The Panel Module PM acts as an external display in cabinet fronts. It is driven by the BM to which it is connected. The maximum distance between PM and BM is 3 meters. o 8 operation indicator o Integrated buzzer o RS 232 interface o Integrated buttons: Lamp test, Horn acknowledgement and Lamp acknowledgement...
  • Page 15: Wiring Diagram

    Wiring diagram: Bus connector CIM Application & Characteristics When you are using modules at different venues, the CIM bus connector is the interface between the cabling. The CIM provides a plug for the standard BCC cable on one side and cage clamp connectors on the other side.
  • Page 16: Additional Information

    BCCS6 Bus cable 0.1m, 6-poles 832.600.033 BCCL6 Bus cable 3.0m, 6-poles 832.600.032 CIM Bus Connector DIN rail-mounted 832.600.095 LSC configuration cable 832.600.903 Replacement insertion tags for the PM (3 pcs.) 832.600.904 Replacement insertion tags for the BM/RM (3 pcs.) 862.332.420 Power supply EcoPower PSS242 24VDC/2A 862.332.430...

Table of Contents