Technical specifications
Materials
- body:
- check valve:
- fitting tailpieces:
Performance
Suitable fluids:
Max. Working pressure:
Operating temperature range:
Max. temperature, NA513, NA514 only:
Opening pressure differential:
Certifications
1. Complies with codes IPC, IRC, UPC and NPC.
2. NSF/ANSI/CAN 372, Drinking Water System
Components-Lead Content Reduction of Lead
in Drinking Water Act, California Health and Safety
Code 116875 S.3874, Reduction in Drinking Water
Act, Vermont Act 193 - The Lead in Plumbing
Supplies Law and Maryland's Lead Free Law HB.372,
certified by ICC-ES, file PMG-1360.
4. PEX crimp fittings designed to ASTM F 1807.
5. PEX expansion fittings designed to ASTM F 1960.
Function
A check valve ensures that water only flows in a single direction of a
plumbing or hydronic system. The NA51 series low-lead serviceable
inline spring check valves, ideal for residential and commercial
applications, feature union connections with a variety of end connection
options for easy installation and maintenance. The valve is constructed
of a stainless steel body and low-lead brass or copper tailpieces. It
complies with low lead laws and listed by ICC-ES, and meets codes
IPC, IRC, UPC and NPC for use in accordance with the US and
Canadian plumbing codes.
dual union connections, flowing Cv
www.caleffi.com
17............................................sizes ½" and ¾"
30...........................................sizes 1" and 1¼"
75........................................sizes 1½" and 2"
color black in NA512 (sizes ½" & ¾")
color white in NA513 & NA514 (sizes 1" - 2")
water and non-hazardous glycol solution up to 50%
NA512: 32 to 250°F (0 to 121°C)
NA513, NA514: 32 to 150°F (0 to 65°C)
0.25 psi (size ½" through 1¼")
1
NA1070.01
NA51 series
stainless steel
.
NBR, POM
low-lead brass or copper
150 psi (10 bar)
for one hour: 190°F (88°C)
0.50 psi (size 1½" & 2")

Advertisement

loading

Summary of Contents for CALEFFI NA51 Series

  • Page 1 Function A check valve ensures that water only flows in a single direction of a plumbing or hydronic system. The NA51 series low-lead serviceable inline spring check valves, ideal for residential and commercial applications, feature union connections with a variety of end connection options for easy installation and maintenance.
  • Page 2: Safety Instruction

    100°F (38°C). Failure to follow these instructions could result in property damage and/or personal injury. CAUTION: Make sure that all the connecting pipework is water tight. Caleffi shall not be liable for damages resulting from stress corrosion, misapplication or misuse of it products.
  • Page 3: Consigne De Sécurité

    ATTENTION: S'assurer que tous les raccordements sont étanches. Caleffi ne pourra être tenue responsable des dommages résultant de la corrosion, d’une mauvaise utilisation ou une mauvaise utilisation des produits.
  • Page 4 Dimensions NPT female B’ sweat press* PEX crimp expansion *Lay length: ½" press- 2 inch. ¾" press- 2 inch. 1" press- 4 inch. 1 ¼" press- 5 inch. 1 ½" press- 5 inch. 2" press- 7 inch.
  • Page 5 Code (lb) 5 /8" NA51200 1" metric, no fittings (1) NA51240 ½" NPT Male " NA51249 ½" SWT " NA51243 ½" NPT Female 4" NA51246 ½" press 15 /16 " NA51247 15 /16 ½" PEX crimp " 9 /16" NA51248 ½"...
  • Page 6: Installation

    Installation The Caleffi NA51 series spring check valve may be installed in either a vertical or horizontal position. Pipe lines should be thoroughly cleaned and flushed before installing the check valve. A strainer should be installed ahead of the check to prevent unnecessary malfunction. Install shutoff valves on inlet and outlet of check to facilitate servicing and maintenance.
  • Page 7 NOTES...
  • Page 8 Typical application diagram on each branch return cold variable speed recirculation circulator water check valves Caleffi North America, Inc. 3883 West Milwaukee Road Milwaukee, WI 53208 05-2023 T: 414.238.2360 F: 414.238.2366 For Technical Support call 1-414-338-6338, or email techsupport.us@caleffi.com...

This manual is also suitable for:

Na5212 seriesNa5213 seriesNa5214 seriesNa51200Na51249Na5124 ... Show all