IEEE 1394
Number of ports .....................................................3
Camera interface ....................................................IEEE 1394a
Speed......................................................................100, 200, or 400 Mbps
Available bus power ...............................................Refer to the

Physical Characteristics

Dimensions ............................................................10.2 cm × 12.7 cm × 6.4 cm
Weight ....................................................................1 kg (2.2 lb)
Refer to Appendix B, Mounting Information, of the NI CVS-1450 Series User Manual for dimensional
drawings of the NI CVS-1450 device.
Environmental
The NI CVS-1450 device is intended for indoor use only.
Operating temperature
Vertical mounting position.............................0 to 55 °C
All other positions..........................................0 to 45 °C
Storage temperature ...............................................–20 to 85 °C
Humidity ................................................................10 to 90% RH, noncondensing
Pollution Degree ....................................................2
Operating shock (IEC 68-2-27) .............................50 g, 6 ms half sine, 3 shocks per side;
Operating vibration
Random (IEC 60068-2-34) ............................10 to 500 Hz, 5 G
Swept Sine (IEC 60068-2-6)..........................10 to 500 Hz, 5 g
Approved at altitudes up to 2,000 m.
Safety
The NI CVS-1450 device meets the requirements of the following standards for safety and electrical
equipment for measurement, control, and laboratory use:
EN 61010-1, IEC 61010-1
UL 61010-1
CAN/CSA-C22.2 No. 61010-1
Note
For UL and other safety certifications, refer to the product label or visit ni.com/
certification, search by model number or product line, and click the appropriate link the
Certification column.
© National Instruments Corporation
Power Requirements
(4 in. × 5 in. × 2.5 in.)
30 g 11 ms half sine, 3 shocks per side