When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine
the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension
cord are in good working condition. Make repairs or replacements before using the vacuum
cleaner. Only use extension cords that are rated for outdoor use.
120V
Ampere rating
More than
Not more than
0
6
10
12

EXTENSION CORDS

25ft (7.62m)
6
18
10
18
12
16
16
14
Length of Extension Cord
50ft (15.24m)
100ft (30.48m) 150ft (45.72m)
A.W.G. Wire Size
16
16
16
12
6
16
14
14
12
14
12
Not recommended