Frymaster FPRE314 Installation & Operation Manual page 33

Table of Contents

Advertisement

6.2.3 Basket Lift Problems
Problem
Basket lift
movement is noisy,
jerky, or erratic.
6.2.4 Filtration Problems
Problem
Filter pump won't
start.
Filter pump runs
but oil does not
return to frypot and
there is no bubbling
oil.
Probable Causes
Lack of lubrication on basket lift
rods.
Probable Causes
A. Power cord is not plugged in or
circuit breaker is tripped.
B. Pump motor has overheated
causing the thermal overload
switch to trip.
C. Blockage in filter pump.
Test: Close the drain valve and
pull the filter pan out from the
fryer. Activate the pump. If the
pump motor hums for a short time
then stops, the probable cause is
blockage of the pump itself.
Blockage in filter pan suction tube.
Test: Close the drain valve and pull
the filter pan out from the fryer.
Activate the pump. If bubbling oil
occurs, there is a blockage in the
filter pan suction tube.
Corrective Action
Apply a light coating of
Lubriplate
white grease to the rod and
bushings.
Corrective Action
A. Verify that the power cord is
fully plugged in. If so, verify
that circuit breaker is not
tripped.
B. If the motor is too hot to touch
for more than a few seconds, the
thermal overload switch has
probably tripped. Allow the
motor to cool at least 45
minutes then press the Pump
Reset Switch.
C. Pump blockages are usually
caused by sediment buildup in
the pump due to improperly
sized or installed filter paper
and failure to use the crumb
screen. Call FAS.
The blockage may be caused by
sediment buildup or, if solid
shortening is used, solidified
shortening in the tube. Use a thin,
flexible wire to remove the
blockage. If the blockage cannot
be removed, call FAS.
6-7
or similar lightweight

Advertisement

Table of Contents