Troubleshooting; Spare Parts - Saey 94 MF Installation And User Manual

Table of Contents

Advertisement

Available languages

Available languages

S
94 / S
94 T
AEY
AEY
OP
9 T
ROUBLESHOOTING
Fault
The fire doesn't burn
well
Glass blackens quickly
A strange odour and
smoke develops during
first use
Condensation
Smoke hindrance
Chimney fire
10 S
PARE PARTS
We stock most spare parts for our products. Note down the reference number of your product and request the
spare part from your point of sale. For spare parts both under and outside of warranty, please contact your point of
sale.
Cause
Inappropriate fuel
Poor chimney draught (min 8 Pa)
Insufficient combustion air
Inappropriate fuel
Insufficient combustion air
Baking in of the paint
High difference in temperature
Poor chimney draught (min 8 Pa)
Fuel isn't entirely burnt
Innapropriate fuel
Overcharge
Poor maintenance
Solution
Only use recommended fuels
Check the air-tightness of the flue
Close the chimney's cleaning hatches
Clean the flue
Check diameter flue outlet and supply of
combustion air
Check if extractor fans are operating in
the same room
Only use recommended fuels
Check diameter flue outlet and supply of
combustion air
Check if extractor fans are operating in
the same room
The odour and smoke will dissapear after a
while
Open the door for 2-3 min when lighting the
fire. Do not leave the fire unattended!
Check the air-tightness of the flue
Close the chimney's cleaning hatches
Clean the flue
Only fill when flames are dying out
Immediately close the air supply and contact
the fire department
ENGLISH
2018
40

Advertisement

Table of Contents
loading

This manual is also suitable for:

94 top9494 top mf

Table of Contents