Specifications
P214 SPECIFICATIONS
Flow Range
Accuracy (3 cP)
Maximum Operating Pressure
Weight
Recommended Filtration
Port Size(s)
Fluids
MATERIALS OF CONSTRUCTION
External
Wetted
O-Rings
FREQUENCY TRANSMITTER
Output Signal
K-Factor
Power Supply Requirements
Ambient Operational Range
Metered Liquid Temp Range
(based on 20° ambient)
Compliance
ANALOG TRANSMITTER
Output Signal
Power Supply Requirements
Ambient Operational Range
Metered Liquid Temp Range
(based on 20° ambient)
Compliance
P-Series User Manual Rev2022
5 to 10,000 cc/min
± 0.2% of reading over a 200:1 range
3000 psi (210 bar)
3.8 kg
10 micron
3/8 inch NPT, #6 SAE, or manifold mount
Most non-aqueous, hydrocarbon based fluids
Stainless steel, type 303
Stainless steel, type 303, 440C; Cobalt based carbide
Standard: Viton®
Optional: Teflon®, Perfluoroelastmer, Neoprene
Standard: 5 Vdc, single phase
Optional: Quadrature 5 Vdc, two phase
Current sinking, 20 mA max., single phase
Single Phase: 90 pulses/cc
Two Phase: 180 pulses/cc, 4x decoded
(45 pulses/cc/phase, 1x decoded)
5-26 Vdc @ 30ma
-40°C to 80°C, Single piece - Two piece to 110°C
-40°C to 90°C, Standard model
-40°C to 225°C, Two piece, ultra high temperature model
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex
db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1,
Groups C and D, Tx
Any range of ± 10V or ± 20mA linearized and damped
with anti-dither protection
12Vdc @ 90 mA, 24Vdc @ 45 mA
-40°C to 80°C, Single piece - Two piece to 110°C
-40°C to 90°C, Standard model
-40°C to 225°C, Two piece, ultra high temperature model
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex
db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1,
Groups C and D, Tx
17