Max P Series User Manual page 10

Positive displacement piston flow meter
Table of Contents

Advertisement

Electrical Installation Instructions - 5-pin Turck Connectors
Applies only to transmitters with 5-pin, M12 style connectors. For hazardous location transmitters with 1/2 inch conduit
connections, please refer to the EXInstall sheet.
Frequency Output Transmitters (PN ending N/-)
4
3
5
1
2
Power (+5 to 26 Vdc)
Common
Pulse Output
Output Phase B (Quad only)
Case Ground
Current Sinking Wiring (PN ending S/-)
A current sinking device uses the transmitter's transistor output to act as a
switch. Positive DC voltage must be applied to the transmitter's output pin (#2).
When the pulse output is triggered, this voltage is grounded to zero volts by the
transmitter. Warning: Use a 5k ohm resistor to limit current if your system does
not have other means to limit current into the transmitter.
Analog Current or Voltage Output Transmitters (PN ending A/-, B/-, C/-, or D/-)
4
3
5
1
2
Power *
Common
Signal Output (+)
Signal Output (—)**
Case Ground
* Analog transmitters with part numbers ending in A/- or C/- are 24Vdc power.
Part numbers ending in B/- or D/- are 12Vdc power.
** To minimize signal noise, analog output transmitters are fully isolated. If
your PLC does not ground the negative signal input, there is a risk of a ground
shift that could drive the signal out of the range of detection. To prevent this
from occuring, install a 10k pull down resistor between Common and Signal
Output (-).
P-Series User Manual Rev2022
Turck®
Connector
Mating Cable
PCA
Pin #
Wire Color
Label
V+
1
Brown
Com
4
Black
Ph A
2
White
Ph B
5
Grey
Case
3
Blue
Turck®
Connector
Mating Cable
PCA
Pin #
Wire Color
Label
V+
1
Brown
Com
4
Black
Sig
5
Grey
Ret
2
White
Case
3
Blue
7
V+
PLC
V+
Digital
Input
0V
Out
Turck Pin #2 on
Industrial housings
Terminal 3 on ATEX
rated housings
Transmitter