3-4. 嵌合について ENGAGEMENT ························································· 8 3-5. 洗浄について CLEANSING ·························································· 10 3-6. プリント基板およびメタルマスク開口部推奨寸法について PCB AND RECOMMENDED DIMENSIONS OF THE OPENING AREA IN THE METAL MASK ·· 11 3-7. 推奨吸着ノズル寸法について RECOMMENDED DIMENSIONS OF THE PICK-UP NOZZLE ······························ 14 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 1/14...
In order to avoid tilting, it is recommended that the printed circuit boards are fixed by the spacer and something that generates a force to retain the proper mated condition. 押さえ Retaining Force スペーサー Spacer 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 4/14...
嵌合方向への押さえによる固定をお勧め致します。 When such possibility as the product may fall, receive any impact or reaction force from being thrashed is expected,and then it is recommended to fix them in the direction of engagement. 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 5/14...
Also avoid giving any stress to the product with the soldering iron. It could deform tail or melt insulator. はんだごて Soldering iron 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 6/14...
Page 8
KYOCERA Connector Products Corporation (7) PLUG 側は接点が外側に露出している為、実装の際はフラックスの飛散にご注意願います。 In the mounting process,special care is needed so that the exposed contact points on the plug side will be free from splattered flux. 接 触 部 Contact area 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 7/14...
Applying the uneven pressure to the long side of the connector may cause doomed warpage or destruction on the connector depending on the PCB/FPC thickness. Please make sure beforehand when you apply the uneven pressure to the long side of the connector. 長手方向 (△) 短手方向 (×) 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 8/14...
Page 10
The connector is impossible to support the PCB by itself. Without other supporting objects, imperfect mating , peeling of tails or contacting failure may be caused. As supporting objects, use spacers fixed by screws. 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004...
Ultrasonic Wave with Ultrasonic Wave Detergent PINE ALPHA Liquid Isopropyl Alcohol Industrial Air ― ST-100S Medicine Normal Temperature 60℃ Normal Temperature 85℃ Temperature Time 60 Seconds 120 Seconds 60 Seconds 10 Minutes 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 10/14...
As dimensions shown in the drawings are our recommendations. Please feel free to contact us if you have any questions and/or concerns about these dimensions. 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004...
3-7. 推奨吸着ノズル寸法について RECOMMENDED DIMENSIONS OF THE PICK-UP NOZZLE 推奨吸着ノズル寸法は以下の通りです。 The following is the recommended dimensions of the pick-up nozzle. コネクタが基板上に有る際の最大加圧荷重 : 20N Maximum pressure when the connector is placed on a PCB: 20N 5863 SERIES INSTRUCTION MANUAL No.205-03-311 106-03-004 PAGE 14/14...