MENU & KEYS
operated by the even ports (2 and 4). Half of the lights are therefore turned off.
are off, all lights go off. Then there is probably a problem with the air conditioning in the room.
The temperature limits can be altered by pressing the SET key.
Temp-offset
Temp offset
# 0.0 °C
Output power
on the screen. Using the + or – key you can select:
315watt (cdm)
400watt
600watt
630watt DUAL (cdm)
Set output power
1000 Watt EL UHF
Halfforce mode
HALFFORCE MODE
ballasts ensures that the lamps are switched off in an altrernating pattern . (Checkerboard pattern). After 6hrs this
pattern changes to maintain an even light distribution at all times.
After powerfail
After powerfail
Continue
EN
10
MENU & KEYS
LCD back light
LCD back light
ON
By pressing the SET key while LCD back light is displayed on the screen, you can opt to have the LCD backlight
Temperature display
Temperature
in Celsius
Output display
Output display
in Watt
You can select to display the status of dim/boost in the Light screen in Watt or in percentages. Press on the SET key and
Dual room off
Dual room
OFF
With this option, two rooms can be controlled with one controller. OUT1 is room 1 and temp sensor 1 and OUT2 is
Advanced CO2 menu
CO2 SMARTLOGIC2
The new EVO 1.2 Maxi Controller automatically adjusts the best possible CO2 dosing using a special algorithm
that prevents the values being exceeded and always keeps the CO2 level as stable as possible. This self learning
program also ensures that no harmful CO is released by CO2 gas generators, due to the rapid on and off switching
The controller does this during the learning mode. This is normal.
CO2 cur
858ppm:
CO2 setp
870pp
this menu.
EN
11