ABB Relion 670 Series Product Manual page 46

Line differential protection
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Line differential protection RED670 2.0
Product version: 2.0
Table 4. MIM - mA input module
Quantity:
Input resistance
Input range
Power consumption
each mA-board
each mA input
Table 5. OEM - Optical ethernet module
Quantity
Number of channels
Standard
Type of fiber
Wave length
Optical connector
Communication speed
Auxiliary DC voltage
Table 6. PSM - Power supply module
Quantity
Auxiliary DC voltage, EL (input)
Power consumption
Auxiliary DC power in-rush
46
Rated value:
R
± 5, ± 10, ± 20mA
0-5, 0-10, 0-20, 4-20mA
£ 2 W
£ 0.1 W
Rated value
1 or 2 (port A, B for IEC 61850-8-1 / IEEE C37.118 and port C, D for IEC 61850-9-2LE / IEEE
C37.118)
IEEE 802.3u 100BASE-FX
62.5/125 mm multimode fibre
1300 nm
Type ST
Fast Ethernet 100 Mbit/s
Rated value
EL = (24-60) V
EL = (90-250) V
50 W typically
< 10 A during 0.1 s
= 194 Ohm
in
1MRK505310-BEN C
Nominal range:
-
-
-
Nominal range
EL ±20%
EL ±20%
-
-
ABB