Line differential protection RED670 2.0
Product version: 2.0
Binary input/output module, mA and time synchronizating
boards.
Make BIM with 50 mA inrush current the primary choice. BIM with 50 mA inrush current fulfill additional standards. As a consequence the EMC withstand capability
is further increased.
BIM with 30 mA inrush current is still available.
For pulse counting, for example kWh metering, the BIM with enhanced pulse counting capabilities must be used.
Note: 1BIM and 1 BOM included.
Slot position (rear view)
1/2 Case with 1 TRM
3/4 Case with 1 TRM
3/4 Case with 2 TRM
1/1 Case with 1 TRM
1/1 Case with 2 TRM
No board in slot
Binary output module 24 output relays (BOM)
BIM 16 inputs, RL24-30 VDC, 50 mA
BIM 16 inputs, RL48-60 VDC, 50 mA
BIM 16 inputs, RL110-125 VDC, 50 mA
BIM 16 inputs, RL220-250 VDC, 50 mA
BIM 16 inputs, 220-250 VDC, 120mA
BIMp 16 inputs, RL24-30 VDC, 30 mA, for pulse counting
BIMp 16 inputs, RL48-60 VDC, 30 mA, for pulse counting
BIMp 16 inputs, RL110-125 VDC, 30 mA, for pulse counting
BIM 16 inputs, RL220-250 VDC, 30 mA, for pulse counting
IOM 8 inputs, 10+2 output, RL24-30 VDC, 50 mA
IOM 8 inputs, 10+2 output, RL48-60 VDC, 50 mA
IOM 8 inputs, 10+2 output, RL110-125 VDC, 50 mA
IOM 8 inputs, 10+2 output, RL220-250 VDC, 50 mA
IOM 8 inputs 10+2 output relays, 220-250 VDC, 110mA
IOM with MOV 8 inputs, 10-2 output, 24-30 VDC, 30 mA
IOM with MOV 8 inputs, 10-2 output, 48-60 VDC, 30 mA
IOM with MOV 8 inputs, 10-2 output, 110-125 VDC, 30 mA
IOM with MOV 8 inputs, 10-2 output, 220-250 VDC, 30 mA
mA input module MIM 6 channels
SOM Static output module, 12 outputs, 48-60 VDC
SOM static outputs module, 12 outputs, 110-250 VDC
ABB
X
X
A
B
1
C
1
D
1
E
1
E
2
Selection for position #10.
#10
X
X
X
X
X
X
X
X
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
1
1
1
1
1
1
1
1
C
C
C
C
C
C
C
C
1
1
1
1
1
1
1
1
D
D
D
D
D
D
D
D
1
1
1
1
1
1
1
1
E
E
E
E
E
E
E
E
1
1
1
1
1
1
1
1
E
E
E
E
E
E
E
E
2
2
2
2
2
2
2
2
F
F
F
F
F
F
F
F
G
G
G
G
G
G
G
G
H
H
H
H
H
H
H
H
K
K
K
K
K
K
K
K
L
L
L
L
L
L
L
L
1
1
1
1
1
1
1
1
M
M
M
M
M
M
M
M
1
1
1
1
1
1
1
1
N
N
N
N
N
N
N
N
1
1
1
1
1
1
1
1
P
P
P
P
P
P
P
P
1
1
1
1
1
1
1
1
P
P
P
P
P
P
P
P
2
2
2
2
2
2
2
2
U
U
U
U
U
U
U
U
V
V
V
V
V
V
V
V
W
W W
W
W
W
W
W
Y
Y
Y
Y
Y
Y
Y
Y
R
R
R
R
R
R
R
R
T
T
T
T
T
T
T
T
1
1
1
1
1
1
1
1
T
T
T
T
T
T
T
T
2
2
2
2
2
2
2
2
1MRK505310-BEN C
Notes and Rules
Note: Max 3 positions in 1/2 rack, 8
in 3/4 rack with 1 TRM, 5 in 3/4
rack with 2 TRM, 14 in 1/1 rack
with 1 TRM and 11 in 1/1 rack with
2 TRM
X
X
X
X
A
A
A
A
Note: Maximum 4 (BOM+SOM
+MIM) boards.
B
B
B
B
1
1
1
1
C
C
C
C
1
1
1
1
D
D
D
D
1
1
1
1
E
E
E
E
1
1
1
1
E
E
E
E
2
2
2
2
F
F
F
F
G
G
G
G
H
H
H
H
K
K
K
K
L
L
L
L
1
1
1
1
M
M
M
M
1
1
1
1
N
N
N
N
1
1
1
1
P
P
P
P
1
1
1
1
P
P
P
P
2
2
2
2
U
U
U
U
V
V
V
V
W
W
W
W
Y
Y
Y
Y
R
R
R
R
Note: maximum 1 MIM board in
1/2 case
T
T
T
T
Note: SOM must not to be placed
1
1
1
1
in position nearest to NUM; 1/2
case slot P5, 3/4 case 1 TRM slot
T
T
T
T
P10, 3/4 case 2 TRM slot P7, 1/1
2
2
2
2
case 1 TRM slot P16, 1/1 case 2
TRM slot P13
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion red670

Table of Contents