Klarstein HOT & HOT 10033534 Instructions Manual page 36

Table of Contents

Advertisement

Available languages

Available languages

EN
36
Problem
Burner will not light
using ignitor
(Gas issues)
Possible Reason
1. Trying to light
wrong burner
2. Burner not engaged
with control valve
3. Obstruction in burner
4. No gas flow
5. Vapor lock at cou-
pling nut to LP tank
6. Coupling nut ad LP tank
valve not fully connected.
Solution
1. See instructions on
control panel and section
in the Use and Care.
2. Make sure valve
are positioned inside
of burner tubes.
3. Ensure burner tubes
are not obstructed with
spider webs or other
matted, see cleaning sec-
tion of use and care
4. Make sure LP tank is
not empty. If LP tank is not
empty, refer to "sud-
den drop in gas flow.
5. Turn off knobs and
disconnect coupling nut
from LP tank. Recon-
nect and retry.
6. Turn the coupling nut
approximately one-
half to three-quarters

Advertisement