Siemens SINUMERIK ONE MCP 1500 Equipment Manual page 22

Table of Contents

Advertisement

Technical data
Relative humidity
Permissible change in the relative humid‐
ity
Pollution degree
Mechanical environmental conditions
Classification of the mechanical environ‐
ment
Vibration load during operation
Shock load during operation with shock-
sensitive components
EMC conducted / radiation
1) The system installer ensures the system is sealed properly according to IP65, IP classification has not been
checked by UL, UL TYPE 1.
2) Open-type equipment according to UL 61010.
3) The customer must ensure that the product, with the rear cover to be attached by the customer, meets
the requirements for flame resistance of the material according to UL 94 V-1 and the mechanical stability /
fire protection requirements / touch protection according to UL 61010.
4) If power supply units with primary-side supplies up to 600 V AC (line-to-neutral voltage) have to be
deployed, the transient voltages on the primary side of the power supply unit must be limited to 4000 V.
5) Connect the device only to a 24 V DC power supply that is compliant with protective extra-low voltage
(PELV) requirements according to UL 61010.
1) Le réalisateur du système est responsable de l'étanchéité selon IP65, la classification IP n'a pas fait l'objet
d'essais UL, UL TYPE 1.
2) Matériel ouvert selon UL 61010
3) Le client est tenu de veiller à ce que les exigences en matière de résistance à l'incendie du matériel selon
UL 94 V-1 et les exigences en matière de stabilité mécanique/protection incendie/protection contre les
contacts selon UL 61010 soit remplies par la mise en oeuvre d'une enveloppe anti-incendie externe.
4) Si une alimentation avec tension primaire jusqu'à 600 V CA (conducteur - point neutre) est mise en
œuvre, limiter les surtensions transitoires au primaire de l'alimentation à 4 000 V.
5) Raccorder l'appareil uniquement à une alimentation 24 V CC qui répond aux exigences de très basse
tension de protection (TBTP) selon UL 61010.
Note
The 24 V DC current source must be adapted to the input data of the device (see "Electrical data").
Note
In a residential environment, this product can cause high-frequency interference, which may
make interference suppression measures necessary.
• Have the installation and commissioning with appropriate radio interference suppression
measures performed by qualified personnel.
22
MCP 1500
5 ... 90% (without condensation)
Max. 6%/h
2 (only use indoors)
Class 3M2 according to EN 60721-3-3
Frequency range: 10 – 200 Hz
Deflection at 9 – 18 Hz: 1.5 mm
Acceleration at 18 – 200 Hz: 2 g
Acceleration: 5 g
Shock duration: 30 ms
Load: 3 x in each direction
Class C2 according to EN 61800-3
Equipment Manual, 05/2022, A5E52027171B AA
Acceleration: 15 g
Shock duration: 11 ms
ONE MCP Part 2: MCP 1500

Advertisement

Table of Contents
loading

Table of Contents