Siemens SINUMERIK ONE MCP 1500 Equipment Manual page 23

Table of Contents

Advertisement

Note
Damage to components by coolants and lubricants
The SINUMERIK operator components have been designed for industrial use, particularly on
machine tools and production machines. This also takes into account the use of commercially
available coolants and lubricants. The use of aggressive compounds and additives can damage
components and result in their failure.
Avoid contact between the operator components with coolants and lubricants, as resistance to
all coolants and lubricants cannot be guaranteed.
Emergency stop button
Rated voltage
Current rating, max.
Current rating, min.
Switching capacity
Conditional rated short-circuit current
B
10d
Note
The quantitative assessment of the emergency stop safety function must be based on the B
values corresponding to the used standards (e.g. ISO 13849-1) under consideration of the
respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B
button are taken into account.
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA
values only apply when the technical properties of the emergency stop
10d
24 V DC
3 A
1 mA
DC 13 according to EN 60947-5-1
10 A gL/gG according to EN 60947-5-1
500000
Technical data
10d
23

Advertisement

Table of Contents
loading

Table of Contents