Function CODE No. (DN Code) Table (Includes All Functions Needed to Perform Applied Control on Site)
D
N
I
e t
m
Filter display delay timer 0000: None
01
Dirty state of filter
02
Central control address
03
Specific indoor unit
04
priority
Heating temp shift
06
Existence of [AUTO]
0d
mode
Cooling only
0F
T
y
p
e
10
n I
d
o
r o
u
n
t i
c
a
p
a
c
y t i
11
12 Line address
13 Indoor unit address
Group address
14
Louver type
(Air direction
19
adjustment)
Temp difference of
[AUTO] mode selection
1E
COOL
HEAT,
HEAT
COOL
Automatic restart of
28
power failure
Selection of option/error
2A
input (CN70)
HA terminal (CN61)
2E
select
3
1
V
e
n
l i t
t a
n i
g
a f
n
c
o
n
r t
l o
32 TA sensor selection
3
3
T
e
m
p
e
a r
u t
e r
u
n
t i
s
e
e l
Swing mode
F0
Louver fixed position
F1
(Louver No.1)
Louver fixed position
F2
(Louver No.2)
Louver fixed position
F3
(Louver No.3)
Louver fixed position
F4
(Louver No.4)
0002: 2500H
0004: 10000H
0000: Standard
0001: High degree of dirt (Half of standard time)
0001: No.1 unit
0099: Unfixed
0
0
0
: 0
N
o
p
i r
r o
y t i
0000: No shift
0002: +2°C
0000: Provided
0001: Not provided (Automatic selection from connected outdoor unit)
0000: Heat pump
0001: Cooling only (No display of [AUTO] [HEAT])
0
0
0
: 1
4-way Cassette
0
0
0
: 0
U
n
x i f
e
d
0001: No.1 unit
0001: No.1 unit
0000: Individual
0002: Follower unit of group
0000: No louver
0002: (1-way Cassette type, Ceiling type)
0003: (2-way Cassette type)
0004: (4-way Cassette type)
0
0
0
: 0
0
d
e
g
(For setup temperature, reversal of COOL/HEAT by ± (Data value)/2)
0
0
0
: 0
N
o
n
e
0000: Filter input
0002: None
0000: Usual
0002: Fire alarm input
0
0
0
: 0
U
n
a
v
a
a l i
b
e l
0000: Body TA sensor
t c
0
0
0
0
° :
C
(
t a
a f
c
o t
y r
s
h
p i
0001: Standard
0003: Cycle swing
0000: Release
0005: Downward discharge position
0000: Release
0005: Downward discharge position
0000: Release
0005: Downward discharge position
0000: Release
0005: Downward discharge position
D
e
s
c
i r
t p
o i
n
0001: 150H
0003: 5000H
to
0064: No.64 unit
0
0
0
: 1
P
i r
r o
y t i
0001: +1°C
to
0010: +10°C
(Up to +6 recommended)
0
0
0
1
o t
0
0
3
4
to
0030: No.30 unit
to
0064: No.64 unit
0001: Header unit of group
0001: Swing only
o t
0
0
1
: 0
1
0
d
e
g
0
0
0
: 1
R
e
s
a t
t r
0001: Alarm input (Air washer, etc.)
0001: Leaving-ON prevention control 0000: Usual
0
0
0
: 1
A
v
a
a l i
b
e l
0001: Remote controller sensor
m
e
n
) t
0
0
0
: 1
F °
0002: Dual swing
0001: Horizontal discharge position
0001: Horizontal discharge position
0001: Horizontal discharge position
0001: Horizontal discharge position
– 94 –
A
t
s
h
p i
m
e
t n
According to type
0000: Standard
0099: Unfixed
0
0
0
: 0
N
o
p
i r
r o
y t i
0002: +2°C
(Floor type 0000: 0°C)
0001: Not provided
0000: Heat pump
D
e
p
e
n
d
n i
g
o
n
m
o
d
l e
type
A
c c
o
d r
n i
g
o t
c
a
p
a
c
y t i
type
0099: Unfixed
0099: Unfixed
0099: Unfixed
According to type
0
0
0
: 3
3
d
e
g
(Ts±1.5)
0
0
0
: 0
N
o
n
e
0002: None
(HA terminal)
0
0
0
: 0
U
n
a
v
a
a l i
b
e l
0000: Body TA sensor
0
0
0
0
° :
C
0001: Standard
0000: Not fixed
0000: Not fixed
0000: Not fixed
0000: Not fixed