Install the Shock into the frame by securing front
eyelet with a Guide Pin. Apply Loctite to the
threads and grease shaft of Small Collet Axle
(3.14). Install small Collet Axle (3.14) through the
lower Extender (3.22), through the Shock, and
thread into Upper Extender (3.23).
Torque: 15 Nm
Grease wedge and threads and install Small
Collet Wedge Bolt (3.10) into Axle.
Torque: 8 Nm
Take precautions to prevent the shock striking/
contacting the downtube.
16
Install Univesal Hanger (3.34) into frame.
Do not use grease. Note that hanger cap bolt
is reverse threaded.
Torque: 25 Nm
13
Install Female 8x45mm bolt (3.18) with Washer
(3.21) through front Shock Eyelet and secure
with M6 Male Bolt (3.19) and Washer (3.20).
Apply Loctite to threads of M6 Male Bolt (3.19).
Torque: 10 Nm
Check all frame bolts to ensure that no
linkages are loose and there is proper fit
on all components.
14
Install Housing Clamp Cap (3.8) onto the drive-
side main pivot axle with a M4 x 16L FHCS (3.25).
Tighten until snug. Hardware can be torqued to
2-3 Nm after housing installation.