RIB L1 Manual page 27

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
EVENT
DIP 1 ON (hold-to-run mode)
Or failure of a safety device
DIP 2 ON (full stroke programming)
DIP 2 ON > DIP 1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety device
EVENT
No transmitter code entered
DIP 1 ON > DIP 2 ON - transmitter code programming for full opening
DIP 1 ON > DIP 3 ON - transmitter code programming for pedestrian opening
DIP 1 ON > DIP 2 ON > DIP 3 ON - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Alarm from Encoder
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm from Self-learning failed
ACCESSORIES -
For the connections and the technical data of the optional equipments follow the relevant handbooks.
RADIO TRANSMITTER SUN
SUN 2CH
cod. ACG6052
SUN CLONE 2CH
cod. ACG6056
SUN-PRO 2CH
cod. ACG6210
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
WARNING SIGNALS DURING OPERATION
2 Tones every 5 s for 1 minute
(It is renewed by giving a command)
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
5 Tones every 5 s for 1 minute
(It is renewed by giving a command)
(It is renewed by giving a command)
Continuous tone for 10 s with 2-s pause.
Not active when DIP 2 in OFF
SUN 4CH
cod. ACG6054
SUN CLONE 4CH
cod. ACG6058
SUN-PRO 4CH
cod. ACG6214
BUZZER STATUS
FLASHER STATUS
OFF
OFF
OFF
10 s tone with 2 s pause
BUZZER STATUS
FLASHER STATUS
OFF
OFF
OFF
OFF
1 Tone
1 Tone
OFF
OFF
2 Tones
BUZZER STATUS
FLASHER STATUS
OFF
1 Tone
2 Tones
OFF
Flashes for 1 minute
Flashes for 1 minute
OFF
6 Tones every 5 s
OFF
RADIO MODULE 433MHz
27
DL1 LED STATUS
OFF
Flashes ON/OFF 250 ms
OFF
Flashes ON/OFF 500 ms
OFF
Flashes ON/OFF 500 ms
OFF
On steady
DL12 LED STATUS
OFF
Flashes red/green
OFF
Flashes red for 10 s
OFF
Flashes green for 10 s
OFF
Flashes orange for 10 s
OFF
Turns green once
OFF
Turns red once
OFF
Turns red once
OFF
Runs 6 green flashes
OFF
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
OFF
Led DL6 turns OFF
OFF
Led DL7-8 turns OFF
OFF
Led DL9-10 turns OFF
OFF
Led DL1 flashes ON/OFF 250 ms
No led combined
OFF
No led combined
DL14 led is OFF
OFF
Led DL12 is steady on green.
OFF
No leds matched
OFF
Blue led flashes once every 5 s
OFF
No leds matched
G
B
code ACG8069