Please leave this leaflet with the fan for the benefit of the user. UK customers: If you have any queries before or after installing this product call the Xpelair Technical Hotline+44 (0) 344 879 3588 or email customer.services@glendimplex.com Our engineers are there to help you during normal office hours.
Cleaning and maintenance of the appliance shall not be made by children. All Xpelair Simply Silent LVCV Constant Volume SELV fans have the following features: Constant Volume fan that automatically adjusts itself to maintain installed air flow rates.
Page 3
Back plate fixing positions Transformer Overall Dimensions and knockouts...
Wiring and setting up Where to locate the fan. Locate it as high as possible. At least 110mm from the edges of the mounting surface to the centre of the hole. As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room (e.g.
Page 6
A 100mm diameter prepared hole. Appropriate ancillaries for termination. These items are available from Xpelair: 3m flexible ducting Ref: 89663AA. If the duct passes through a cold space use insulated duct ref: 89847AA. Soffit Grille Ref: 89742AW XCT100 – Condensation Trap. Ref: 89749AA. Fitted immediately above the fan, this prevents water ingress due to condensation forming in the duct above the fan and running down.
Page 7
If installing in a ceiling, appropriate termination ancillaries are required. Follow instructions provided. Mount the back-plate. Feed the mains cable through the cable entry hole in the back plate to the terminals. Insert the fan tube of the back-plate into the wall duct/ceiling as before. Fasten the back-plate to the wall/ceiling using appropriate fasteners.
Pictorial view inside transformer box detailing terminal block positions For fixed wiring circuits the protective fuse for the appliance must not exceed 5A. Electrical Connections...
Page 9
Fan Settings. SPEED SETTING The fans are factory set to bathroom speed, but have two speed settings for different applications. Select either kitchen or bathroom speed by connecting the jumper between the centre and kitchen or bathroom speed pin on the jumper (see Figure LVCV4S /LVCV4R–...
Page 10
LED flash sequence to indicate hour run: LED off for 2 seconds to indicate the start of the count, then : 0 to 2000 hours : LED on for 1 short flash (0.5s on / 0.5s off) 2000 to 3000 hours : LED on for 2 short flashes ...
Page 11
This page has been left blank for the addition of any notes you may wish to make.
Page 12
You must provide to Xpelair or its authorised agents on request the original receipt as proof of purchase and - if required by Xpelair - proof of delivery. If you are unable to provide this documentation, you will be required to pay for any repair work required.