All wiring should be done by a qualified electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The appliance,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
Millivolt System Valve Models
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
to the receptacle that is provided. Leave approximately 6" of wire
in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
IPI System Valve Models
1.
Power for switched and live sides of receptacle must come from
the same power source. (One circuit breaker on main panel
must switch all power off.)
2. From the wall box to the fireplace a 3-wire conductor with
ground is recommended, however two 2-wire conductors with
grounds may be used in place of a 3-wire conductor with a
ground if the black wires from the thermostat and blower switch
are identified.
3.
Two wall switches may be used to activate the receptacle plugs
independently.
BLACK
TO 120V
WHITE
CIRCUIT
BREAKER
GROUND
39634-2-0720

ELECTRICAL CONSIDERATIONS

CAUTION
Figure 13
DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE
DOUBLE SWITCH BOX
(INSTALLER PROVIDED)
BLACK
WHITE
FIREPLACE
CONTROL
COMPARTMENT
3 WIRE, GROUNDED
CONDUCTOR
(BY OTHERS)
Figure 14