Locating Fireplace; Electrical Considerations - Empire Comfort Systems DVCT40CSP95N-1 Installation Instructions Manual

Direct-vent zero clearance gas fireplace heater
Hide thumbs Also See for DVCT40CSP95N-1:
Table of Contents

Advertisement

NOTICE: When installing this appliance against an exterior wall,
insulate to applicable insulation codes.
NOTICE: Island and Room Divider installation is possible as long
as the horizontal portion of the vent system does not exceed 18 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in room divider or flat
on wall corner positions, maintain a minimum of 6 inches between
the perpendicular wall and the opening of the appliance.
All wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes.
Before making the electrical connection, make sure that the main power supply is disconnected. The appliance, when installed,
must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical
Code ANSI/NFPA 70 (Latest Edition).
Junction Box
A factory-installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
with wire nuts to the control module power leads already fed into
the junction box.
Attach black to black and white to white. The ground wire should be
attached to the ground on the junction box. See Figure 11.
Interface/Battery Holder
The user interface/battery holder must be mounted within a distance
allowed by the attached 12 foot harness. As shipped, this harness is
already fed through a strain relief on the bottom of the component
access box and is attached to the User Interface/Battery Holder.
NOTICE: If an auxiliary device is to be used, its wiring may be fed
through the junction box strain relief. Auxiliary device amperage
limit is 5 amps.
NOTICE: A one inch diameter hole should be use to pass wiring
through studs.
Page 14

LOCATING FIREPLACE

ELECTRICAL CONSIDERATIONS

CORNER
INSTALLATION
CAUTION
JUNCTION BOX CONNECTIONS
ELECTRICAL POWER TO UNIT
JUNCTION BOX / CONTROL MODULE
VERTICAL
FRAMING
MEMBER
Figure 12
CABINET
INSTALLATION
ISLAND
INSTALLATION
ROOM DIVIDER
INSTALLATION
Figure 10
120 VOLT POWER SUPPLY
JUNCTION BOX
BLACK (HOT)
WHITE (NEUTRAL)
GROUND TO JUNCTION BOX
Figure 11
USER INTERFACE/
BATTERY HOLDER
MUST BE INSTALLED
USER INTERFACE
INTO WALL JUNCTION
HARNESS
BOX. (ORANGE LOW-
VOLTAGE BOX
RECOMMENDED.)
FLUSH WALL
INSTALLATION
40651-2-0320

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvct40csp95p-1

Table of Contents