Levoit Classic 36-Inch - Tower Fan Manual

Levoit Classic 36-Inch - Tower Fan Manual

Advertisement

Levoit Classic 36-Inch - Tower Fan Manual

Package Contents

1 x Tower Fan
2 x Base
1 x Remote Control
1 x Quick Start Guide
1 x User Manual

Specifications

Model LTF-F361-WUS
Power Supply AC 120V, 60Hz
Rated Power 39W
Timer 1–12 hr
Fuse 2.5 Amp, 125V (3.6 x 10 mm)
Dimensions 6.5 x 6.5 x 36.2 in / 16.5 x 16.5 x 92 cm
Weight 8.5 lb / 3.9 kg

SAFETY INFORMATION

To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines.

General Safety

  • Only use your tower fan as described in this manual.
  • Do not use your tower fan outdoors.
  • To protect against electric shock, do not immerse the tower fan cord, plug, or housing in water or spray with liquids.
  • Do not place the tower fan in a window. Keep your tower fan away from water and wet or damp areas.
  • Keep your tower fan away from open flames, heat sources, or other heating and cooking appliances.
  • Do not use where combustible gases, vapors, metallic dust, aerosol (spray) products, or fumes from industrial oil are present.
  • Do not place anything into any opening on the tower fan.
  • Do not use with any openings blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
  • Avoid contact with moving fan parts.
  • Do not hang or mount the tower fan on a wall or ceiling.
  • Only use the tower fan on a dry and level surface.
  • Close supervision is necessary when the tower fan is used by or near children.
  • Children should be supervised to ensure that they do not play with the tower fan.
  • Children should be supervised to ensure they do not insert fingers or objects into the vent openings.
  • Children should not clean or perform maintenance on the tower fan without supervision.
  • Keep the inside of the tower fan dry. To prevent moisture buildup, avoid placing in rooms with major temperature changes.
  • Unplug the tower fan when not in use for an extended period of time.
  • Do not use other items or third-party parts as replacement parts for this tower fan.
  • Do not use your tower fan if it is damaged or not working correctly, or if the cord or plug is damaged. Do not try to repair it yourself. Contact Customer Support.

  • To reduce the risk of fire or electric shock, do not use this tower fan with any solid-state speed controls (such as a dimmer switch).
  • This tower fan is not to be used by persons (including children) with reduced physical, sensory, or mental capacities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Not for commercial or industrial use. Household use only.

Power Cord & Fuse

  • Your tower fan has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plug in that outlet. Do not alter the plug in any way.
  • Turn off the tower fan before removing the plug from the outlet. To unplug, grab the plug and pull from the outlet. Never pull from the power cord.
  • Keep the tower fan near the outlet it is plugged into. The use of an extension cord is not recommended.
  • Always turn the tower fan off and unplug it when not in use and before moving, cleaning, or servicing the fan.
  • Never place the cord near any heat source.
  • Do not cover the cord with a rug, carpet, or other covering. Do not place the cord under furniture or appliances.
  • To avoid a tripping hazard, keep the cord out of areas where people walk often. Place the cord where it will not be tripped over and safely coil the cord.
  • A loose fit between the AC outlet and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace a loose or worn outlet.
  • Your tower fan has a fuse built into the plug for overload protection. If the tower fan is overloaded or short-circuits, the fuse will blow. To replace the fuse, see Replacing the Fuse.
  • If the replacement fuse blows, a shortcircuit may be present. Please contact Customer Support.
  • If the power cord is damaged, it must be replaced by Arovast Corporation or similarly qualified persons in order to avoid an electric or fire hazard. Please contact Customer Support.
  • Your tower fan should only be used with 120V, 60Hz electrical systems. Do not plug into another type of outlet.

Electromagnetic Fields (EMF)
Your Levoit tower fan complies with all standards regarding electromagnetic fields (EMF). If handled properly and according to the instructions in this user manual, the appliance is safe to use based on scientific evidence available today.

This product contains a coin/button battery.

CHEMICAL BURN HAZARD.
KEEP OUT OF REACH OF CHILDREN.

Swallowing can lead to chemical burns, perforation of soft tissue, and death. Severe burns can occur within 2 hours of ingestion. Seek medical attention immediately.

  • Place sticky tape around both sides of the battery and dispose of it immediately in an outdoor trashcan or recycle safely;
  • Store spare batteries securely;
  • Empty recycling units on a regular basis;
  • Use non-transparent containers to keep the batteries out of view.

Unfortunately, it is not obvious when a button or coin battery is stuck in a child's esophagus (food pipe). The child might:

  • Cough, gag or drool a lot;
  • Appear to have a stomach upset or a virus;
  • Be sick;
  • Point to their throat or stomach;
  • Have pain in their abdomen, chest, or throat;
  • Be tired or lethargic;
  • Be quieter or more clingy than usual or otherwise "not themselves";
  • Lose their appetite or have a reduced appetite;
  • Not want to eat solid food / be unable to eat solid food.

These sorts of symptoms vary or fluctuate, with the pain increasing and then subsiding.
A specific symptom to button and coin battery ingestion is vomiting fresh (bright red) blood. If a child does this, seek immediate medical help.
The lack of clear symptoms is why it is important to be cautious with "flat" or spare button or coin batteries in the home and the products that contain them. Be aware that even used button or coin batteries may cause injury.

GETTING TO KNOW YOUR TOWER FAN

Device Overview - Part 1

  1. Control Panel
  2. LED Display
  3. Vents
  4. Power Cord
  5. Remote Control
  6. Back Cover
  7. Base

Control Panel
Device Overview - Part 2 - Control Panel

  1. Oscillate Button
  2. Fan Mode Button
  3. Advanced Sleep Button
  4. Timer Button
  5. Fan Speed Button
  6. On/Off Button

LED Display
Device Overview - Part 3 - LED Display

  1. Normal Fan Mode Indicator
  2. Advanced Sleep Mode Indicator
  3. Fahrenheit Indicator
  4. Sound Off Indicator
  5. Auto Mode Indicator
  6. Turbo Mode Indicator
  7. Hour Indicator
  8. Oscillate Indicator

CONTROLS & DISPLAY

On/Off Button

  • Tap to turn the tower fan on/off.

Fan Mode Button

  • Tap to cycle through fan modes: Normal Fan, Turbo, and Auto (see Fan Modes).
  • Press and hold for 3 seconds to turn selection sounds on/off.

Timer Button

  • Tap to cycle through timer options from 1–12 hours.
  • Press and hold to quickly cycle through options in increments of 1 hour.

Advanced Sleep Button

  • Tap to turn Advanced Sleep Mode on/off (see Advanced Sleep Mode)

Oscillate Button

  • Tap to turn oscillation on/off.
  • The tower fan has a 90° angle of oscillation.

Fan Speed Button

  • Tap to cycle through fan speeds from 1 (low) to 5 (high).

REMOTE CONTROL

The remote control can be used to control any of the tower fan's functions from a distance. The remote must be within 16 ft / 5 m of the tower fan to work.
Note:

  • Remove the plastic tab from the remote control's battery compartment before using.
  • To replace the battery.
    Remote control Overview

Sound Off Button (Remote Only)

  • Press to turn selection sounds on/off.

GETTING STARTED

  1. Remove all packaging.
  2. Snap the two pieces of the base together. [Figure 1.1]
    Getting Started - Step 1
  3. Unscrew the plastic nut from underneath the tower fan. [Figure 1.2]
  4. Secure the base to the tower fan with the plastic nut. [Figure 1.3]
  5. Place the tower fan on a flat, stable surface such as the floor.
  6. When using the tower fan, allow at least 15 inches / 38 cm of clearance from the front of the tower fan. Keep away from anything that would block air flow, such as curtains. [Figure 1.4]
    Getting Started - Step 2

USING YOUR TOWER FAN

  1. Plug in and tap to turn on the tower fan. The fan will start on low.
    • The display will show "01" and will turn on for 5 seconds.
    • Then, the display will show the current room temperature for 15 seconds.
  2. Tap to change fan speed from 1 (low) to 5 (high).
  3. Optionally, tap to select a different fan mode, or tap to turn Advanced Sleep Mode on/off.

Fan Modes

Tap to cycle through fan modes: Normal Fan, Turbo, and Auto.

Normal Fan Mode

Use Normal Fan Mode to manually control the tower fan's functions, such as fan speed, oscillation, and timer.

  • This is the tower fan's default mode.
  • will show on the display.

Turbo Mode

Use Turbo Mode with air conditioning to quickly circulate air in your home.

  1. Tap and select Turbo Mode. will show on the display.
  2. The tower fan automatically starts oscillating and operates at fan speed 5.
  3. When the room temperature drops 5°F, the fan speed will decrease to 3, then the tower fan will enter Auto Mode and automatically adjust fan speed according to the room temperature.

Auto Mode

Use Auto Mode for automatic fan speed adjustments according to the room temperature.

  1. Tap and select Auto Mode. will show on the display.
  2. The starting fan speed is determined by the current room temperature.
Room Temperature Fan Speed
70°–73°F 1
73°–77°F 2
77°–80°F 3
80°–86°F 4
> 86°F 5

Note: The max ambient working temperature is 104°F.

  1. Optionally, tap to manually adjust the fan speed while in Auto Mode. The tower fan will then operate according to the following logic:
    1. If the temperature increases 5°F, the fan speed will increase one level.
    2. If the temperature decreases 5°F, the fan speed will decrease one level.

Advanced Sleep Mode

Advanced Sleep Mode is an optimized sleep mode that takes into account the stages before you sleep, during sleep, and as you wake up.

  1. Tap to turn Advanced Sleep Mode on. will show on the display.
    1. After 5 seconds, the display will turn off and selection sounds will be disabled.
    2. The starting fan speed is determined by your current fan speed when you select Advanced Sleep Mode.
  2. After 1 hour, the tower fan will decrease fan speed as the room temperature stabilizes.
  3. The tower fan then begins oscillating and enters Auto Mode. This automatically adjusts the fan speed according to the fluctuating room temperature as you sleep and wake up.
    1. If the temperature increases 5°F, the fan speed will increase one level.
    2. If the temperature decreases 5°F, the fan speed will decrease one level.
  4. Tap or to turn Advanced Sleep Mode off.

Auto Display Off

  1. Press and hold for 3 seconds to turn on Auto Display Off.
  2. After 60 seconds of no operation, the display will automatically turn off (except in Advanced Sleep Mode).
  3. Tap any button to temporarily turn the display back on. If you don't tap another button, the display will turn back off after 60 seconds.
  4. Press and hold for 3 seconds to turn off Auto Display Off.

Standby Mode

  • The tower fan is in Standby Mode when it is turned off, but plugged in.
  • Tap to turn the tower fan on.

Memory Function

When the tower fan is in standby or turned off and unplugged, it will remember all its previous settings, except for timer.

CARE & MAINTENANCE

Cleaning the Tower Fan

  • Unplug before cleaning.
  • Wipe the outside of the tower fan with a soft, dry cloth. If necessary, wipe the housing with a damp cloth, then immediately dry.
  • Use a vacuum, duster, or compressed air to clean the inside of the tower fan.
  • If necessary, use a screwdriver to remove the back cover and clean the inside of the tower fan. [Figure 2.1]

    Note:
    • Make sure the tower fan is turned off before removing the back cover.
    • Clean the internal parts with a dry cloth.
  • Do not clean with abrasive chemicals or flammable cleaning agents.

Replacing the Remote Control Battery

  1. Insert a coin/button battery into the slot and rotate counterclockwise to remove the battery compartment [Figure 2.2].
  2. Remove the old battery.
  3. Replace with a new 3V CR2025 battery. Make sure the polarities match.
  4. Replace the battery compartment.

Replacing the Fuse

  1. Unplug the tower fan. Grab the plug and pull from the outlet. Never pull from the power cord.
  2. Open the fuse cover on the plug by sliding the fuse cover toward the metal prongs. [Figure 2.3]
  3. Carefully remove the blown fuse with tweezers or a small tool. Make sure not to break the glass fuse.
  4. Risk of fire: Only replace the fuse with a 2.5 Amp, 125V fuse (3.6 x 10 mm). Do not use any other type of fuse. [Figure 2.4]
  5. Slide the fuse cover closed.
    Note: If the replacement fuse blows, a short-circuit may be present. Please contact Customer Support.


RISK OF FIRE
Do not replace the plug if it is damaged. If the plug is damaged in any way, stop using the tower fan and contact Customer Support.

Storage

If not using the tower fan for an extended period of time, cover the tower fan and store in a cool, dry place to avoid moisture damage.

TROUBLESHOOTING

Problem Possible Solution
Tower fan will not turn on or respond to button controls. Plug in the tower fan.
Check to see if the power cord is damaged. If so, stop using the tower fan and contact Customer Support.
Plug the tower fan into a different outlet.
Tower fan may be malfunctioning. Contact Customer Support.
Tower fan makes an unusual noise while the fan is on. Make sure the tower fan is operating on a hard, flat, level surface.
Tower fan may be damaged, or a foreign object may be inside. Stop using the tower fan and contact Customer Support. Do not try to repair the tower fan.
Tower fan randomly turns off. Tower fan is malfunctioning. Stop using the tower fan and contact Customer Support.

If your problem is not listed, please contact Customer Support.

Questions or Concerns?
Please contact us Mon–Fri, 9:00 am–5:00 pm PST/PDT
at support@levoit.com or at (888) 726-8520.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Levoit Classic 36-Inch - Tower Fan Manual

Advertisement

Need Assistance?

Do you have a question about the Classic 36-Inch that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents