Levoit LV600HH - Hybrid Ultrasonic Humidifier Manual

Levoit LV600HH - Hybrid Ultrasonic Humidifier Manual

Also See for LV600HH:

Advertisement

Levoit LV600HH - Hybrid Ultrasonic Humidifier Manual

Package Contents

1 x Hybrid Ultrasonic Humidifier
1 x Remote Control
1 x 3V CR2025 Battery (Pre-Installed)
3 x Aroma Pads (1 Pre-Installed)
3 x Absorption Pads (1 Pre-Installed)
1 x Cleaning Brush
1 x User Manual

Specifications

Power Supply AC 120V, 60Hz
Rated Power 280W
Effective Range 430–753 ft ² / 40–70 m²
Water Tank Capacity 1.5 gal / 6 L
Max Cool Mist Output 300 mL/h
Max Warm Mist Output 500 mL/h
Dimensions 11.3 x 7.0 x 10.5 in / 28.7 x 17.8 x 26.7 cm
Weight 6.5 lb / 2.95 kg

SAFETY INFORMATION

To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines.

General Safety

  • Only use the humidifier as described in this manual.
  • Place the humidifier and cord so that the humidifier will not be knocked over.
  • When not in use, turn the humidifier off and disconnect from power source by removing the plug from the outlet.
  • Do not overfill the water tank, as this may cause electric shock.
  • Do not use the humidifier in wet environments.
  • Keep the humidifier out of reach from children.
  • Do not open the base or remove the water level sensor for self-servicing.
  • Always unplug the humidifier from the power outlet before cleaning the humidifier or detaching the water tank from the humidifier base.
  • Always make sure the humidifier is placed on a flat, level surface before operation.
  • Only fill the water tank with purified or distilled water. Never fill the water tank with any other liquids unless directed by the manual.
  • Do not place the humidifier near sources of heat, such as stovetops, ovens, or radiators.
  • Do not place the humidifier directly on floors, carpets, or rugs. Only place the humidifier on water-resistant surfaces.
  • Do not use attachments that are not recommended by Levoit for the humidifier.
  • Do not cover the nozzles while the humidifier is on. Doing so may damage the humidifier.
  • Remove the water tank from the base before moving the humidifier.
  • Do not immerse the humidifier base, power cord, or plug in water.
  • Do not place foreign objects into the humidifier's base or water tank.


Risk of Leaks and Electric Shock

  • Do not add essential oils, supplemental water treatment liquids, or third-party water filters into the water tank or base. This will damage the humidifier and cause leaks. Only add essential oils to the aroma pad.
  • If the humidifier is damaged or is not functioning properly, stop using it and contact Customer Support immediately.

Power and Cord

  • Do not handle the power cord or plug with wet hands. Keep the plug and power cord away from liquids.
  • This humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plug in that outlet. Do not bypass this safety feature.

Not for commercial use. Household use only.

GETTING TO KNOW YOUR HUMIDIFIER

Function Diagram

Device Overview - Part 1 - Function Diagram

  1. Nozzle Cap
  2. Nozzles
  3. Handle
  4. Water Tank
  5. Base
  6. Aroma Box
  7. Aroma Pad
  8. LED Display
  9. Control Panel
  10. Remote Control
  11. Mist Tube
  12. Mist Channel
  13. Absorption Pad
  14. Air Vent
  15. Inner Chamber
  16. Power Cord
  17. Water Tank Cap
  18. Heating Element
  19. Transducer
  20. Insulation Ring

Display

Device Overview - part 2 - Display

  1. High Temperature Warning
  2. Humidity Setting Indicator
  3. Relative Humidity (RH) Percentage
  4. Mist Level
  5. Timer
  6. Warm Mist Setting
  7. Auto Mode Indicator
  8. Low Water Indicator

Control Panel

  1. On/Off Button
  2. Mist Level Button
  3. Warm Mist Button
  4. Humidity Level Button
  5. Timer Button
  6. Auto Mode Button

CONTROLS

Note: The same controls are also on the included remote control.

On/Off Button

  • Turns the humidifier on/off.

Mist Level Button

  • Cycles through mist level settings: low, medium, and high.

Warm Mist Button

  • Turns on warm mist and cycles through warm mist settings: low, medium and high heat.

Humidity Level Button

  • Sets the Relative Humidity (RH) percentage. The humidifier will automatically maintain the target humidity level.
  • Press and hold to cancel your humidity level setting.

Timer Button

  • Sets or cancels a timer.

Auto Mode Button

  • Turns Auto Mode on or off.
  • Press and hold to turn the display off. Press any button (except ) to turn the display back on.

Remote Control

The remote control can be used to control any functions of the humidifier from a distance. It must be within 16 ft / 4.8 m of the humidifier to work.
Note:

  • Remove the plastic tab from the remote control's battery compartment before using. [Figure 1.1]
    Remove the plastic tab
  • To replace the battery.

GETTING STARTED

  1. Place the humidifier on a flat, level, elevated, and water-resistant surface, such as a table or nightstand. Make sure the room is well-ventilated.
    Note:
    • Position the humidifier at least 12 in / 30 cm away from walls and appliances to prevent them from getting wet. [Figure 2.1]
      Getting Started - Step 1
    • Do not place the humidifier directly on floors, carpets, or rugs.
  2. Remove the nozzle cap from the water tank. Use the handle to remove the water tank from the base. [Figure 2.2]
  3. Flip the tank over and twist the water tank cap counterclockwise to remove it. [Figure 2.3]
  4. Pour water into the opening. Fill the tank at least halfway with cold or room temperature water. The maximum capacity is 1.5 gal / 5.6 L.
    Note:
    • We recommend using purified or distilled water in the humidifier.
    • Do not use hot water.
    • Do not add water through the nozzles, mist tube, or into the inner chamber of the base. This may damage the humidifier.
    • Do not add essential oils into the water tank or base. Only add essential oils to the aroma pads.
  5. Replace the water tank cap. Twist the cap clockwise to secure it tightly to the water tank. [Figure 2.4] Wipe off any excess water on the top and bottom of the base.
  6. Carefully place the water tank back onto the base, aligning the water tank cap with the inner chamber. Place the nozzle cap back on top of the water tank. [Figure 2.5]
  7. Plug in the humidifier. The humidifier will light up, then turn off.

USING YOUR HUMIDIFIER

General Operation

  1. Press to turn on the humidifier. The humidifier will start misting on the medium cool mist setting.
    Note:
    • If there is no water in the tank, will light up. Fill the water tank (see Getting Started).
    • The humidifier will be able to run for a longer or shorter time depending on the environmental temperature and humidity.
  2. Optionally, rotate the 2 nozzles to diffuse mist in any desired direction.
    Note:
    • Direct the nozzles away from any furniture to prevent your furniture from getting wet.
    • Do not inhale the mist directly from the nozzles.
  3. Optionally, press to change the mist level.
    Note: If the relative humidity in your room is too high for your comfort, use the low mist setting or turn off the humidifier.
  4. Press to turn off the humidifier.

Warm Mist

  • Press to turn on warm mist. Keep pressing to increase the heat setting for the mist, and to turn warm mist off.

  • Mist may be hot. Do not place your bare hands, face, or other exposed skin over the nozzles while using warm mist.
  • The humidifier may take 15 minutes to warm up before producing warm mist.
  • The warm mist function can be used with Auto Mode.
Warm Mist Chart
Icon Setting
Low Heat
Medium Heat
High Heat

Humidity Level

You can customize the humidity level that the humidifier will maintain.

  1. Press once. The display will show "--".
  2. Keep pressing to set a humidity level between 40% and 80% Relative Humidity (RH).
  3. The display will flash 5 times to confirm your selection.

    Note:
    • After setting the RH percentage, the display will alternate between showing the set RH percentage and the current humidity percentage.
    • To cancel your selection, press and hold for 3 seconds.
  4. Once the humidity of the environment reaches the set RH percentage, the humidifier will automatically stop misting. It will start misting again when the humidity drops to 5% below the set level.

Timer

You can set a timer between 1 and 12 hours.

  • Press repeatedly to choose a time in increments of 1 hour. When you stop pressing , the display will flash 3 times and the timer will start.
  • The humidifier will automatically power off once the timer is finished.
  • To cancel a timer, press repeatedly or press and hold until the display reads "-:--".

Auto Mode

Auto Mode uses the humidifier's sensor to automatically adjust the mist level (or turn it off) to maintain a comfortable level of humidity.

  • Press to turn Auto Mode on/off.
  • The timer and warm mist setting can be used with Auto Mode.
  • Changing the mist level using will cancel the Auto Mode function.

Turning Off the Display

The display will automatically dim after 10 seconds of inactivity. To turn off the display, press and hold for 3 seconds. To turn the display back on, press any button, except .
Note: You can also press on the remote control to turn the display on/off.

Memory Function

While the humidifier is plugged in, it will remember your settings (except Timer) when turned off, and will resume these settings when turned back on.

Automatic Shutoff

The humidifier will automatically turn off when all of the water in the tank has been diffused. will show on the display until more water is added to the water tank. [Figure 3.1]

Absorption Pads

The mineral absorption pads help prevent mineral buildup (scale) inside the humidifier, especially around the heating plate.
Note: To purchase more pads.

Using the Aroma Box

The humidifier can be used as an aroma diffuser.

  1. Turn off the humidifier.
  2. Pull out the aroma box on the left side of the humidifier. [Figures 4.1]
  3. Put 2-3 drops of essential oil on the aroma pad. [Figure 4.2]
  4. Place the aroma box back into the humidifier. Fill the water tank with water and place it back on the base (see Getting Started).
  5. Plug in and turn on the humidifier.
    Note:
    • Do not add essential oils, supplemental water treatment liquids, or third-party water filters into the water tank or base. Only add essential oils to the aroma pad. [Figure 4.3]
      Only add essential oils to the aroma pad
    • The aroma pads can be cleaned and reused after diffusing essential oils (see Cleaning the Aroma Pad).

PREVENTING WATER LEAKS

The water tank may leak if not placed properly on the base.

  • Make sure the silicone ring around the water tank cap is secured at all times. [Figure 5.1]
  • Twist and secure the cap tightly onto the water tank. [Figure 5.2]

    Note: A small gap between the cap and the tank is normal.
  • Wipe off any excess water on the top and bottom of the base.
  • Do not shake the humidifier or place it on an inclined surface. Make sure to place the humidifier on a flat, level surface. [Figure 5.3]
    Do not shake the humidifier

KEEPING THINGS CLEAN

Note:

  • Always make sure the humidifier is unplugged before cleaning.
  • Use a tissue or cloth to clean the nozzle regularly.
  • Do not use liquid detergents to clean the humidifier.
  • We recommend using purified or distilled water instead of tap water for misting to prevent scale buildup in the humidifier.

General Cleaning

You should clean the humidifier every 3 days. Change the water every day or every other day to avoid bacteria growth.

  1. Unplug the humidifier. If you've used the warm mist setting, allow the humidifier to cool before cleaning.
  2. Make sure the nozzle cap is cool. Remove the nozzle cap from the water tank and rinse under clean, running water. Set it aside to air dry.
  3. Remove the water tank from the base and pour out any water from the inner chamber. If you've used the warm mist setting, use caution in case the water is still hot.
  4. Fill the tank with 3 US cups / 710 mL of distilled white vinegar. Replace the cap and gently shake to coat all sides of the water tank. Allow it to sit for at least 1 hour.
  5. Remove the mist channel and mist tube. [Figure 6.1] Detach the mist tube from the mist channel by twisting the tube counterclockwise. Rinse both parts and dry thoroughly.
    Remove the mist channel and mist tube
  6. Remove the absorption pad inside the heating element and rinse. Dry the pad with a clean, dry cloth. [Figure 6.2]
  7. Add 1 US cup / 238 mL of distilled white vinegar to the inner chamber and soak for 1 hour.
    Note: Never submerge the base in water.
  8. Use the included cleaning brush to remove any scale buildup inside the water tank or in the inner chamber. [Figure 6.3]
  9. Pour out the vinegar from the water tank and the inner chamber and thoroughly rinse with warm water.
  10. Dry all parts with a clean, dry cloth. Make sure all parts of the humidifier are completely dry before reassembling or storing.
  11. Do not use the humidifier immediately after disinfecting. This may be a health hazard.
    Note: A 3% hydrogen peroxide solution may also be used instead of vinegar to disinfect the humidifier. Do not mix hydrogen peroxide and vinegar.

Cleaning the Aroma Pad

  1. Pull out the aroma box.
  2. Remove the aroma pad and rinse under warm, running water.
  3. Dry with a clean cloth and place it back into the aroma box.
    Note: Do not pour liquid cleaners or detergents into the aroma pad or box.

Deep Cleaning the Humidifier

Deep clean the water tank every 2 weeks and before and after storing the humidifier for long periods of time. You should also deep clean if there is any mold buildup inside the water tank or inner chamber.
Note: Only use vinegar and water to deep clean the humidifier.

  1. Fill the water tank with 1 US cup / 238 mL of vinegar along with 1 gal / 3.8 L of cold or room temperature water.
  2. Place the humidifier outdoors and allow it to run for 1 hour.
  3. Pour out the mixture and refill with cold or room temperature water. Then, run the humidifier for another hour outdoors.
  4. Rinse the water tank and inner chamber thoroughly under running water.
    Note: Do not submerge the base in water.
  5. If storing, allow the water tank and base to completely air dry before reassembling.

Replacing the Aroma Pads and Absorption Pads

If the aroma pads or absorption pads are stiff even after cleaning, then they need to be replaced. Extra pads are included with the humidifier.
To maintain the performance of your humidifier, only use official Levoit aroma pads and absorption pads. To buy replacement pads, visit Levoit's online store. Go to levoit.com for more information.

Replacing the Remote Control Battery

  1. Remove the battery compartment by pinching the tab in and pulling the compartment out. [Figure 7.1]
    Replacing the Remote Control Battery
  2. Remove the old battery.
  3. Replace with a new 3V CR2025 battery.
    Note: Make sure the polarities match.
  4. Replace the battery compartment.

TROUBLESHOOTING

Problem Possible Solution
No mist comes out of
the nozzles.
Plug in the humidifier and turn it on.
Add at least 2 US cups / 475 mL of purified or distilled water to the water tank.
Clean the humidifier (see Keeping Things Clean).
Water may be in the air vent. Take the water tank off and allow the vent to fully air dry before using again.
Only a small amount of mist comes out of the nozzles. Clean the humidifier, especially the nozzles, air vent, and transducer (see Keeping Things Clean).
Humidifier uses water too quickly. The humidifier uses up water based on the environmental temperature and humidity. If your environment is cold and/or dry, the humidifier will run out of water faster.
Humidifier produces an unusual smell. If the humidifier is new, remove the water cap, and place the water tank in a cool, dry place for 12 hours.
If essential oils were diffused on the aroma pad, rinse the pad and allow it to dry.
Clean the humidifier (see Keeping Things Clean).
Humidifier makes a loud or unusual noise. Make sure the water tank is properly in place (see Getting Started).
Place humidifier on a flat, level surface.
Make sure there is at least 2 US cups / 475 mL of purified or distilled water in the water tank.
When using the warm mist function, the heating element will make a gurgling noise when the water level is low. Add more water to the water tank.
The humidifier may be malfunctioning. Stop using the humidifier and contact Customer Support.
Mist comes out from the base. Make sure the water tank is properly in place (see Getting Started).
Water visibly leaks from the humidifier. Stop using the humidifier and see Preventing Water Leaks before using again. If the humidifier continues leaking, contact Customer Support.
White dust appears around or in the humidifier. This is caused by minerals in the water. Use purified or distilled water to fill the humidifier. Avoid using water with high mineral content.
Clean the humidifier every 3 days (see Keeping Things Clean).
The area around the
humidifier is damp or wet.
Run the humidifier on a lower mist setting.
Open a window to ensure proper airflow for the humidifier, or move the humidifier to a more well-ventilated room.
Make sure the water tank is properly in place (see Getting Started).
When replacing the water tank, wipe off excess water from the water tank and base.
If the humidifier is leaking, contact Customer Support.
Mist is not warm after pressing .
Allow the humidifier to heat up for about 15 minutes to produce warm mist.
Clean the heating element of the humidifier (see Keeping Things Clean).
Essential oils don't smell strongly enough. The aroma is intended to be light. This humidifier is not an aroma diffuser.
The humidity level isn't changing in my room. Use a higher mist level setting.
Depending on your environment, the humidifier may take longer to humidify your air.
The humidifier has a maximum effective range of 430–753 ft² / 40–70 m². If the room is larger, the humidifier will not be as effective.
The humidifier does not respond to the remote. Move remote control to within 16 ft / 4.8 m of the humidifier.
Remove the plastic tab from the battery compartment.
Change the battery (see Replacing the Remote Control Battery).
Incorrect humidity percentage is
displayed.
The room may be larger than the humidifier's effective range. Move to a room smaller than 430–753 ft² / 40–70 m².
Moisture may have built up inside of the humidity sensor. Turn off the humidifier and allow the sensor to air dry. Make sure the nozzles are facing away from the sensor.
If the humidifier is placed within 12 in / 30 cm of a wall or in a corner, the built-in humidity sensor cannot provide a proper reading for the relative humidity in the room.
The humidity sensor will give an improper reading if it is exposed to dust. Avoid using the humidifier in dusty rooms.
If the display always shows either 30% or 90% RH when you start the humidifier, the humidity sensor is malfunctioning. Contact Customer Support.

If your problem is not listed, please contact Customer Support.
If you have any questions or concerns, please reach out to us at support@levoit.com.

Find @LevoitLifestyle on social media for wellness + style inspiration. We make every space mindful and chic.
@LevoitLifestyle
#LevoitLove • #LevoitLifestyle

Questions or Concerns?
Please contact us Mon–Fri, 9:00 am–5:00 pm PST/PDT
at support@levoit.com or at (888) 726-8520.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Levoit LV600HH - Hybrid Ultrasonic Humidifier Manual

Advertisement

Need help?

Need help?

Do you have a question about the LV600HH and is the answer not in the manual?

Questions and answers