Levoit Classic 200 - Ultrasonic Cool Mist Humidifier Manual
![]()
Package Contents
1 x Ultrasonic Humidifier
3 x Aroma Pads (1 Pre-Installed)
1 x Cleaning Brush
1 x User Manual
1 x Quick Start Guide
Specifications
Power Supply | AC 120V, 60Hz |
Rated Power | 30W |
Water Tank Capacity | 1.05 gal / 4 L |
Max Run Time | Up to 40 hours on low mist setting Note: The humidifier will be able to run for a longer or shorter time depending on the environmental temperature and humidity. |
Noise Level | ≤ 30dB |
Effective Range | 285–376 ft² / 24–35 m² |
Dimensions | 14 x 8 x 6 in / 35.4 x 20.2 x 15.2 cm |
Weight | 3.5 lb / 1.6 kg |
![burn hazard]()
![shock hazard]()
To reduce the risk of fire, electric shock, or other injury, follow all instructions and safety guidelines.
General Safety
- Only use the humidifier as described in this manual.
- Place the humidifier and cord so that it will not be knocked over. Do not place near large pieces of furniture or in hightraffic areas.
- When not in use, turn the humidifier off and disconnect from power by removing the plug from the outlet.
- Do not use the humidifier in wet environments.
- Keep the humidifier out of reach from children.
- Do not open the base or remove the water level sensor for self-servicing.
- Always unplug your humidifier from the power outlet before cleaning your humidifier or detaching the water tank from the humidifier base.
- Always make sure to place the humidifier on a flat, level surface before operation.
- Only fill the water tank with clean water. Never fill the water tank with any other liquids.
- Do not place the humidifier near sources of heat, such as stovetops, ovens, or radiators.
- Do not place the humidifier directly on floors, carpets, or rugs.
- Do not use other items as replacement parts for this product.
- Do not cover the nozzles while the humidifier is on. Doing so may damage the humidifier.
- Remove the water tank from the base before moving the humidifier.
- Do not immerse the humidifier base, power cord, or plug in water.
- If the humidifier is damaged or is not functioning properly, stop using it and contact Customer Support immediately.
- Not for commercial use. Household use only.
![]()
Risk of Leaks and Electric Shock
- Do not add essential oils, supplemental water treatment liquids, or water filters into the water tank or base chamber. This will damage the humidifier and cause leaks. Only add essential oils to the aroma pad.
Plug & Cord
- Ensure that the plug fits properly into a polarized socket.
- Do not handle the power cord or plug with wet hands. Keep the plug and power cord away from liquids.
Your humidifier has a polarized plug (one prong is wider than the other), which fits into a polarized outlet only one way. This is a safety feature to reduce the risk of electric shock. If the plug does not fit, reverse the plug. If it still does not fit, do not use the plug in that outlet. Do not bypass this safety feature.
READ AND SAVE THESE INSTRUCTIONS
GETTING TO KNOW YOUR DEVICE
![Levoit - Classic 200 - GETTING TO KNOW YOUR DEVICE GETTING TO KNOW YOUR DEVICE]()
- Nozzles
- Nozzle Cover
- Water Tank Handle
- Mist Outlet
- Water Tank
- Cleaning Brush
- Cleaning Brush Storage
- Base
- Control Button
- Insulation Ring
- Transducer
- Float Housing
- Float
- Mist Tube
- Water Tank Windows
- Air Outlet
- Base Chamber
- Power Cord
- Water Tank Cap
- Silicone Sealing Ring
- Water Valve
- Noise Silencer
- Aroma Pad
- Aroma Box
- Air Inlet
GETTING STARTED
- Remove all packaging.
- Choose a hard, flat location for the humidifier at least 12 in / 30 cm away from any walls. The surface must be water-resistant.
![Levoit - Classic 200 - GETTING STARTED - Choosing a location GETTING STARTED - Choosing a location]()
- Mist should be directed away from walls, furniture, bedding, and appliances.
![]()
Filling & Refilling
- Remove the nozzle cover from the water tank. Use the handle to lift the water tank from the base.
![]()
- Flip over the water tank and remove the water tank cap by twisting it counterclockwise.
![]()
- Fill the tank with room-temperature water. Do not fill with hot water.
![]()
Note: We recommend using purified or distilled water to fill the tank.
![]()
- Do not add water directly into the base chamber.
![]()
- Do not add water through the mist tube.
- Do not add essential oils into the humidifier. Only add essential oils to the aroma pad.
![]()
- Do not use water treatment liquids, or third-party water filters in this humidifier.
- Replace the water tank cap and align the arrow with the lock.
![Levoit - Classic 200 - Filling & Refilling - Replacing the water tank cap Filling & Refilling - Replacing the water tank cap]()
- Place the tank back on the base and replace the nozzle cover onto the water tank.
![]()
USING YOUR UNIT
- Plug in the humidifier.
- Tap
to turn your humidifier on. Tap repeatedly to change the mist setting.
![]()
- Rotate the nozzles to adjust the direction of the mist.
![]()
- When your room has reached a comfortable humidity level, turn your humidifier to a lower setting or turn it off. A comfortable humidity level is above 40% and below 60%.
![]()
Note:
- Low mist is the default setting when the humidifier is first turned on.
- If there is no water in the tank or the tank is removed, the humidifier will stop misting, the fan will turn off after 5 seconds, and
will turn red.
Button Color | Function |
Blue | Low mist setting is selected |
Orange | Medium mist setting is selected |
Purple | High mist setting is selected |
Red | No water in tank or tank not on base |
Off | Humidifier is off |
| Button light has been turned off |
Note: Press and hold
for 3 seconds to turn off the button light.
Important Tips
Your humidifier must have the correct level of water in the base chamber to work properly. If there is too much water in the base chamber, the humidifier cannot create mist.
- Never pour water directly into the base chamber. Only add water to the water tank. The humidifier will automatically release the correct amount of water into the base chamber.
![]()
- Avoid moving or shaking the humidifier. This may cause the water tank to release too much water into the base chamber.
![]()
- Before moving the humidifier, turn it off, unplug it, and remove the water tank.
- If your humidifier doesn't produce mist correctly, check the max water line to see if there is too much water in the base chamber. Pour out extra water if water is over the max line.
![]()
Note: The max water line is only for this purpose. Do not pour water into the base chamber.
Using the Aroma Box
Your humidifier can be used as an aroma diffuser.
- Push the aroma box at the back of the base and pull it out.
![]()
- Put 2–3 drops of essential oil on the aroma pad.
![]()
- Place the aroma box into the humidifier. The humidifier will automatically diffuse aroma when used.
Note:
- Do not add essential oils, water treatment liquids, or third-party water filters into the water tank or base chamber. Only add essential oils to the aroma pad.
- The aroma pads can be cleaned and reused after diffusing essential oils (see Cleaning the Aroma Pad).
Preventing Leaks
The water tank may leak if not placed properly.
- Make sure the silicone sealing ring around the water tank cap is secured at all times.
- Twist and secure the cap tightly onto the water tank. Make sure the arrow is aligned with the lock.
![Levoit - Classic 200 - Using your Unit - Preventing Leaks Using your Unit - Preventing Leaks]()
Note: A small gap between the cap and the tank is normal.
- Wipe any excess water off the top and bottom of the base.
- Do not shake the humidifier.
- Make sure to place the humidifier on a flat, level surface.
CARE & MAINTENANCE
Note:
- All maintenance should be done on a waterresistant surface, such as a kitchen counter.
- Change the water daily to avoid bacteria growth.
- Use a tissue or cloth to clean the nozzles regularly.
- If not using the humidifier for 1 week or longer, do not leave water inside. Clean and dry the humidifier instead.
Cleaning
You should clean your humidifier every week, and when you're ready to store it.
Note:
- Never immerse the base in water or liquid.
Do not place any part of the humidifier in a dishwasher. - Do not use detergents to clean the humidifier.
- Unplug the humidifier.
- Remove and rinse the nozzle cover.
![]()
- Remove the water tank from the base. Pour out any water from the tank and base chamber.
![Levoit - Classic 200 - Cleaning - Step 1 - Remove the water tank Cleaning - Step 1 - Remove the water tank]()
- Rinse the tank and base chamber with room temperature water.
![Levoit - Classic 200 - Cleaning - Step 2 - Rinse the tank Cleaning - Step 2 - Rinse the tank]()
- To descale the humidifier:
- Fill the tank with 3 US cups / 710 mL of distilled white vinegar.
![]()
- Replace the tank cap and swish the vinegar around the tank.
![]()
- Place the tank on the base and soak for 15–20 minutes. Vinegar will drain into the base chamber and loosen scale (mineral buildup) in the tank and in the base chamber (including the transducer and float).
![]()
- Remove the tank and pour out any vinegar.
![Levoit - Classic 200 - Cleaning - Step 3 Cleaning - Step 3]()
- Flip the tank over and remove the tank cap and noise silencer. To remove the noise silencer, press the release tab and gently pull away from the humidifier.
![Levoit - Classic 200 - Cleaning - Step 4 Cleaning - Step 4]()
- Place the tank cap and noise silencer in a small container and fill with enough vinegar to cover them. Soak for 15–20 minutes.
![]()
- Use a soft cloth and the included cleaning brush to remove scale.
![]()
- Rinse all parts until any vinegar smell is completely gone.
![Levoit - Classic 200 - Cleaning - Step 5 Cleaning - Step 5]()
- Dry all parts with a cloth. Make sure all parts are completely dry before reassembling or storing.
Note: Brush can be stored in the brush storage slots in the base.
Cleaning the Aroma Pad
- Press the aroma box to release it from the base, and pull it out.
![]()
- Remove the aroma pad and rinse under warm, running water.
![Levoit - Classic 200 - Cleaning the Aroma Pad - Step 1 Cleaning the Aroma Pad - Step 1]()
- Dry with a clean cloth and place it back into the aroma box.
![Levoit - Classic 200 - Cleaning the Aroma Pad - Step 2 Cleaning the Aroma Pad - Step 2]()
Note: Do not pour liquid cleaners or detergents into the aroma pad or box.
Reassembling
- Flip the water tank over and replace the noise silencer on the tank.
![]()
- Refill the tank, if necessary. Replace the water tank cap by firmly twisting it back in place, aligning the arrow with the lock.
![Levoit - Classic 200 - Care & Maintenance - Reassembling Care & Maintenance - Reassembling]()
- Store the brush in the brush storage slots in the base.
![]()
- Place the tank properly on the base and replace the nozzle cover onto the water tank.
![]()
TROUBLESHOOTING
Problem | Possible Solution |
Humidifier doesn't turn on. | Plug in the humidifier and turn it on. |
Add purified or distilled water to the water tank. |
Little or no mist comes out. | Turn the mist level to a higher setting. |
Fill the water tank. |
There may be too much water in the base chamber. Empty the base chamber. Refill the water tank (not the base chamber) and place the water tank properly onto the base. |
Make sure the air inlet on the bottom of the base is not blocked. The humidifier should not be set on carpet or other |
surfaces that may block the air inlet. |
Make sure the nozzles are not blocked or clogged. |
Make sure the humidifier is on a level surface. |
The water temperature may be too low. Turn the mist level to the highest setting and let the humidifier run for a while, then adjust to the desired setting. |
If the water tank or base was washed with detergent, rinse thoroughly with clean water to remove any detergent. |
Humidifier uses water too quickly. | The humidifier uses up water based on the environmental temperature and humidity. If your environment is cold and/or dry, the humidifier will run out of water faster. |
Humidifier produces an unusual smell. | If the humidifier is new, remove and rinse the water tank cap, and place the water tank in a cool, dry place for 12 hours. |
If essential oils were placed on the aroma pad, rinse the pad under clean water, and allow it to dry. |
Clean the water tank and base chamber (see Care & Maintenance ). |
Humidifier makes a loud or unusual noise | Make sure the water tank is properly in place (see Getting Started). |
Set mist level to a lower setting. |
The humidifier may be malfunctioning. Stop using the humidifier and contact Customer Support. |
Empty the base chamber. Refill the water tank (not the base chamber) and place the water tank properly onto the base. |
White dust appears around the humidifier. | We recommend using purified or distilled water to fill the humidifier. Avoid using water with high mineral content. |
Clean the humidifier (see Care & Maintenance). |
Water leaks from the humidifier. | Make sure the silicone sealing ring around the water tank cap is secure and tighten the water tank cap. |
Condensation forms around humidifier or windows. | Humidity may be too high. Turn down the mist level, turn off the humidifier, or open a door or window to the room. |
Mold grows inside the humidifier. | Clean the water tank and inner chamber regularly (see Care & Maintenance). |
is red. | Fill the water tank. |
Place the water tank properly on the base. |
Essential oils have little or no smell. | Add more essential oils. For best results, use pure essential oils. |
If your problem is not listed, please contact Customer Support
Questions or Concerns?
Please contact us Mon–Fri, 9:00 am–5:00 pm PST/PDT at support@levoit.com or at (888) 726-8520.
Find Us Online
Search for @LevoitLifestyle #LevoitLove #LevoitLifestyle on social media for tips, special deals, giveaways, inspiration, and more.
If you have any questions or concerns, please reach out to us at support@levoit.com. We hope you enjoy your new humidifier!
![]()
Documents / ResourcesDownload manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Levoit Classic 200 - Ultrasonic Cool Mist Humidifier Manual
Need help?
Do you have a question about the Classic 200 and is the answer not in the manual?
Questions and answers