TAPS REB1000, REB2000D, REB3500, NGM1000,
NGM2000D, NGM3000, NGM3500, NGM3500D
Important Note
Mixer must be installed to the requirements of
AS/NZS 3500 by a qualified plumber.
Before installing the tap check the water
pressure is between 150kPa and 450kPa.
1. Drill a hole 34mm to 36mm if the basin/
Bench do not have any access.
Screw in the fixing bolts and tighten
with a screwdriver.
2.
Screw in the two flexible hoses.
3.
Place the tap unit in the pre-punched
hole in the sink or basin with the flexible
hoses going first.
4.
From underneath the basin, fix rubber
seal, fixing plate and fixing nuts with a
3
A.
Please flush out new pipe work prior to
connecting the new mixer.
B.
All mixers should be installed with isolating
stop valves.
socket set or a tube spanner to clamp
the mixer onto the basin. Ensure the tap
set is firmly attached.
5.
Connect the mixer to the water supply by
connecting the two flexible hoses to the
isolating stop valves.
6.
After full connection to water supply,
remove aerator and flush out before
initial water test.
7.
Replace the aerator.
Important Information
We do not recommend dismantling
the internal parts of the tap set.