Download Print this page

Hitachi RAS-08HT Installation Instructions Manual page 5

Split inverter type room air conditioner

Advertisement

Assembly of access panel of the indoor unit
Additional fixing to the installation
plate and the base
Note: To let the indoor unit attach closely to the wall, the base and
the installation plate can be tightened and secured by using
the item ② screw after piping work is completed, and then
assembly the access panel.
1
Fitting the installation plate
Secure the installation plate by using the intermediate post
between walls.
Level
Special screw
Inscription
Thread
When fitting the installation plate, the figures printed on the
bottom of the packaging carton of the unit can be used to
position.
Contour of the shape of the indoor unit
Series
08~15
a
Series
19、24
a
服務蓋
Access panel
螺絲遮蓋
Screw cover
Installation plate
Piping hole
Plummet
Secure it with 4 or
more special
screws
Models
RAS-08HT
RAS-10HT
RAS-15HT
RAS-19HT
RAS-24HT
RAS-30HT
b
b
Step 1:
Align the round fixing axis with the rectangular hole below the
base and insert it all the way upward.
Step 2:
Align the hooks on both sides with the guiding slots on the
base and push slightly upward from the bottom of the access
panel until the base engages in the access panel and the
surfaces are flush. (A clear "da" sound can be heard when the
hook is engaged.)
Step 3:
Tighten the fixing screw that fixes the access panel to the
bottom of the unit.
Step 4:
Press the screw cover into the access panel.
Installation procedure for fitting the installation plate on
the wall.
1. Drilling on the wall.
Wall
Knock in or
screw in
3. Secure the installation plate on the wall by
using Item
unit : mm
a
b
82
88
93
88
88
88
(The diagram is an instance of RAS-20NF)
5
Base
Screw
Installation plate
2. Aligning with the
hole on the
installation plate.
Installation plate
Special
screw
Wall
special screws.
Ceiling
Above 70mm
Special screw
RAS-08HT)

Advertisement

loading