Handling condensate from the outdoor unit
Hanging
first
The outdoor unit base is provided
with a drain hole for condensed
water.
To drain condensed water by using
the drain hole, lift the unit about
70mm or more above the ground,
and then fit the drain elbow as
shown in the above diagram.
Screw it tight in clockwise direction
at an angle about 40∘.
Install the outdoor unit on Series.
Check that the condensed water
can drain normally.
The drainpipe (VP16) should be
supplied locally.
+
Indoor Units Installation Instructions
Removal of access panel of the indoor unit
Maximum allowable height of tilt for the indoor and outdoor u n i t
Models
RAS-08HT
RAS-10HT
RAS-15HT
RAS-19HT
RAS-24HT
RAS-30HT
Press in
The condensed water drain tray for the indoor unit can be fitted
from the left or right side. Hence, the installation plate must be
kept in a Series when fixing it, or the side fitted with the drain line
must be slightly tilted downward. Otherwise, the condensed
water may spill out.
輕摳此處可拆下
Fixing screw
固定螺絲
dig here slightly to remove
服務蓋
Access panel
a (mm)
7
10
Step 1:
Remove the fixing screws of the
screw cover beneath the unit
and the access panel.
螺絲遮蓋
Screw cover
Step 2:
Support the access panel under
the base with two hands and
apply pressure inward on the
"
hook inside the access panel is
released from the base.
(A clear sound of "da" can be
heard
released.)
Step 3:
After the hooks on both sides are
released,
beneath the unit can be removed
downward with both hands. After
the access panel is removed,
there has more space for wiring
and piping work.
4
" of two sides, until the
when
the
hook
the
access
panel
is